• Address

    C-188, Sector 31-D, P&T Society,

    Korangi Industrial Area,

    Karachi-74900,

    Pakistan

     

  • Call us on

     +92-21-35070751

     +92-300-5776703

  • Mail us @

    info@pakplc.com

     

  • Communication

S7-300 Communication modules

Description

Communication processors are used for connecting S7-300 to the different bus systems / communication networks as well for point-to- point link. According to application case and module different protocols and different bus systems are available like PROFIBUS DP or Industrial Ethernet.

Point-to-point connection
Point-to-point link via communications processors (CPs) is an extremely powerful and low-cost alternative to bus systems.The advantage of point-to-point links over bus systems is especially pronounced when only a few (RS 485) devices are to be connected to the SIMATIC S7.
The CPs can also easily link third-party systems to the SIMATIC S7. Thanks to the great flexibility of the CPs, different physical transmission media, transmission rates or even customized transmission protocols can be implemented.
For each CP, there is a configuring package on CD with electronic manual, parameterization screen forms and standard function blocks for communication between the CPU and the CP.
The configuration data are stored in a system block and backed up in the CPU. When modules are replaced, the new module is therefore immediately ready for use.
The interface modules for the S7-300 are available in three versions, each with one interface for the different physical transmission media.

Applications

Communication modules allow connection of the SIMATIC S7-300 for instance to:

  • SIMATIC S7 and SIMATIC S5 programmable controllers, and systems from many other manufacturers

  • PCs, programming devices, hmi devices

  • Field devices

  • Printers

  • Robot controls 

  • Modems

  • Scanners, bar code readers, etc.

 

Benefit

• Reduced start-up times due to the easy configuration with STEP 7
• Reduced downtimes and service times in the event of a fault through LED displays 

Design and function

The CPs have a rugged plastic housing with LEDs for displaying operating states and faults.
They show all advantages of the SIMATIC S7-300- Design, e.g.
• Compact design
• Easy installation 
• User friendly wiring, etc.

 

6ES7340-1AH02-0AE0

1

SIMATIC S7-300, CP 340 Communications processor with RS232C interface (RS-232-C) incl. configuration package on CD

 


6ES7340-1BH02-0AE0

1

SIMATIC S7-300, CP 340 Communications processor with 20 mA interface (TTY) incl. configuration package on CD

 


6ES7340-1CH02-0AE0

1

SIMATIC S7-300, CP 340 Communications processor with RS 422/485 interface incl. configuration package on CD

 


6ES7341-1AH02-0AE0

2

SIMATIC S7-300, CP 341 Communications processor with RS232C interface (RS-232-C) incl. configuration package on CD

 


6ES7341-1BH02-0AE0

2

SIMATIC S7-300, CP 341 Communications processor with 20 mA interface (TTY) incl. configuration package on CD

 


6GK7342-5DA03-0XE0

4

Communications processor CP 342-5 for connection of SIMATIC S7-300 to PROFIBUS DP, S5-compatible, PG/OP and S7 communication

 


6GK7342-5DF00-0XE0

5

Communications processor CP 342-5 FO for connection of SIMATIC S7-300 to PROFIBUS DP, S5-compatible, PG/OP and S7 communication

 


6GK7343-5FA01-0XE0

5

Communications processor CP 343-5 for connection of SIMATIC S7-300 to PROFIBUS, FMS, S5-compatible, PG/OP and S7 communication, 12 Mbit/s, Single-width

 


6GK7343-1CX10-0XE0

1

Communications processor CP 343-1 Lean for connection of SIMATIC S7-300 to Industrial Ethernet via TCP/IP and UDP, Multicast, SEND/RECEIVE with and without RFC1006, Fetch/ Write, S7 communication (server), PROFINET IO device integrated 2-port switch ERTEC 200, Module replacement without PG, SNMP diagnostics, initialization via LAN, 2x RJ45 connection for LAN with 10/100 Mbit/s

 


6GK7343-1EX30-0XE0

2

Communications processor CP 343-1 for connection of SIMATIC S7-300 to Industrial Ethernet via ISO and TCP/IP, PROFINET IO controller or PROFINET IO device, integrated 2-port switch ERTEC 200, S7 communication, fetch/write, send/receive with and without RFC1006, Multicast DHCP, NTC- CPU Sync, diagnostic, initialization via LAN, 2x RJ45 connection for LAN with 10/100 Mbit/s

 


6GK7343-1GX31-0XE0

7

Communications processor CP 343-1 Advanced for connection of SIMATIC S7-300 CPU to Industrial Ethernet: PROFINET IO controller a./o. IO device; RT and IRT, MRP, PROFINET CBA; TCP/IP, ISO, UDP, S7 comm., S5-compat. communication (SEND/RECEIVE) with Fetch/Write RFC1006, Multicast Diagnostic extension, SNMP, DHCP, FTP client/server, e-mail, Gigabit-SS1X RJ45 (10/100/1000) PROFINET interface 2x RJ45 (10/100 Mbit); PROFINET CBA; security (firewall/VPN); PROFIenergy

 


6GK7343-1FX00-0XE0

7

Communications processor CP 343-1 ERPC for connection of SIMATIC S7-300 CPU to Industrial Ethernet and to various databases Functions: TCP/UDP, S7 comm., open communication with a. without RFC1006, Multicast, Web server, Clock time via SIMATIC method or NTP, access protection via IP access list SNMP, DHCP, C-plug, Gigabit interface 1x RJ45 (10/100/1000 MB)

 


6FL4343-1CX10-0XE0

8

Notice: Sale will be restricted as of April 30, 2012. http:/support.automation. siemens.com/WW/ view/DE/58567948 Siemens Building Technologies Communications processor CP 343-1 BACnet for connection of SIMATIC S7-300 to BACnet. Additional runtime license for the use of the BACnet protocol on the CP required; Notice: Order only via ORG-ID: A1201396 possible!

 


6GK7377-1AA00-0AA0

9

Compact Switch Module CSM 377 Connection SIMATIC S7-300 and up to 3 further nodes to Industrial Ethernet with 10/100 Mbit/s unmanaged switch, 4 RJ45 ports, External 24 V DC power supply LED diagnostics, S7-300 module, incl. electron. Equipment Manual on CD-ROM

 


6NH7800-3BA00

10

SINAUT ST7, TIM 3V-IE communication module for SIMATIC S7-300 with an RS232 interface for SINAUT communication via a classic WAN and an RJ45 interface for SINAUT communication via an IP-based network (WAN or LAN)

 


6NH7800-3CA00

19

SINAUT ST7, TIM 3V-IE advanced communication module for SIMATIC S7-300 with an RS232 interface for SINAUT communication via a classic WAN and an RJ45 interface for SINAUT communication via an IP-based network (WAN or LAN)

 


6NH7800-4BA00

20

SINAUT ST7, TIM 4R-IE communication module for SIMATIC S7-300, S7-400, PC; with two RS232/RS485 interfaces for SINAUT Communication via standard WAN and two RJ45 interfaces for SINAUT communication via IP-based networks (WAN or LAN)

 


6NH7803-3BA00-0AA0

21

TIM 3V-IE DNP3 communication module for SIMATIC S7-300 with an RS232 interface for DNP3 communication via a classic WAN and an RJ45 interface for DNP3 communication via a IP-based network (WAN or LAN)

 


6NH7803-4BA00-0AA0

22

TIM 4R-IE DNP3 communication module for SIMATIC S7-300, S7-400, PC; with two RS232/RS485 Interfaces for DNP3- Communication via standard WAN and two RJ45 interfaces for DNP3 communication via IP-based networks (WAN or LAN)

 


6GT2002-0GA10

23

MOBY communication module ASM475 for SIMATIC S7 300 and ET200M parameterizable (without front connector)

 

Technical data

application telcontrol g ik10 xx 30337v e small