• Address

    C-188, Sector 31-D, P&T Society,

    Korangi Industrial Area,

    Karachi-74900,

    Pakistan

     

  • Call us on

     +92-21-35070751

     +92-300-5776703

  • Mail us @

    info@pakplc.com

     

automotive industry 2

Industry 1536x1536 Standard
services5

We are Pakplc

With over 32 years of experience

C&M Engineering, geographically located in Asia, business city Karachi the heart of Pakistan. Republic in southern Asia, at 23.30º to 36.45º north latitude, and 61º to 75.31º east longitude, bounded on the north and north-west by Afghanistan, on the north-east by China, on the east and south-east by India, on the south by the Arabian Sea and on the west by Iran. The area of Pakistan is 796,095 sq. km (307,374 sq. mi). The time zone of Pakistan is GMT+5. The capital of Pakistan is Islamabad, the largest city of the country is Karachi.
C&M established in 1986, helping manufacturers succeed and grow is what we do best — with industrial automation control and information solutions designed to give our customers a competitive advantage. From stand-alone, industrial components to enterprise-wide integrated systems, our solutions have proven themselves across a wide range of industries and in some of the most demanding manufacturing environments.

End users and machine builders (OEMs) alike rely on our comprehensive portfolio of equipment, software and serivices to deliver value and help them meet their objectives.

Recognized Expertise

We are recognized System Integrators for Siemens Factory Automation Products

Product development

In house development of Embedded Solutions

Pakistan Engineering Council

 

Siemens Approved System Integrator

channel partners small

ADAM-5000E

8-slot Distributed DA&C System for RS-485


Main Features

  • RS-485 Communication for easy installation and networking
  • 4 or 8 slots for up to 128 points data monitoring card control in one module
  • Extensive software support; Windows DLL, OCX, OPC server and popular HMI/SCADA software drivers
  • Seamlessly integrated with easy-to-use ADAMView data acquisition software
  • Supports ADAM ASCII protocol or Modbus®/RTU protocol
  • Supports Modbus/RTU protocol with user-defined Modbus address
  Datasheet (PDF)
Introduction

The ADAM-5000/485 and ADAM-5000E systems conform to the EIA RS-485 communication standard. This is the industry's most widely used, balanced, bidirectional transmission line standard. RS-485 was specifically developed for industrial applications to transmit and receive data at high rates over long distances.

Specifications
Part Number ADAM-5000E-AE
Communications Communication 3000 VDC
Max.Nodes 128
Protocol ADAM 
ASCII/Modbus 
Protocol
Control System CPU 80188
OS -
RAM -
Power Supply Power Requirement +10 ~ +30 VDC

Reverse engineering

Extensive reverse engineering service for obsolete controls

Maintenance services

Complete electronic and instrumentation maintenance service for all plants and machines

Green energy

Striving to reduce carbon foot-print, and extensively involved in deployment of renewable energy projects.