• Address

    C-188, Sector 31-D, P&T Society,

    Korangi Industrial Area,

    Karachi-74900,

    Pakistan

     

  • Call us on

     +92-21-35070751

     +92-300-5776703

  • Mail us @

    info@pakplc.com

     

automotive industry 2

Industry 1536x1536 Standard
services5

We are Pakplc

With over 32 years of experience

C&M Engineering, geographically located in Asia, business city Karachi the heart of Pakistan. Republic in southern Asia, at 23.30º to 36.45º north latitude, and 61º to 75.31º east longitude, bounded on the north and north-west by Afghanistan, on the north-east by China, on the east and south-east by India, on the south by the Arabian Sea and on the west by Iran. The area of Pakistan is 796,095 sq. km (307,374 sq. mi). The time zone of Pakistan is GMT+5. The capital of Pakistan is Islamabad, the largest city of the country is Karachi.
C&M established in 1986, helping manufacturers succeed and grow is what we do best — with industrial automation control and information solutions designed to give our customers a competitive advantage. From stand-alone, industrial components to enterprise-wide integrated systems, our solutions have proven themselves across a wide range of industries and in some of the most demanding manufacturing environments.

End users and machine builders (OEMs) alike rely on our comprehensive portfolio of equipment, software and serivices to deliver value and help them meet their objectives.

Recognized Expertise

We are recognized System Integrators for Siemens Factory Automation Products

Product development

In house development of Embedded Solutions

Pakistan Engineering Council

 

Siemens Approved System Integrator

channel partners small

Fail-safe S7-400 CPUs

Description

The fail-safe SIMATIC controllers are available for ensuring the functional safety of machines or plants. They meet maximum safety requirements and thus facilitate compliance with relevant standards: EN 954-1 up to Cat. 4, IEC 62061 up to SIL 3, and EN ISO 13849 up to
PL e. As standard and safety programs can be processed simultanously, only one CPU is required to carry out both tasks.



SIMATIC S7-400 CPU 414F-3PN/DP

6ES7414-3FM07-0AB0

SIMATIC S7-400, CPU414F-3 PN/DP Central processing unit with: Work memory 4 MB, (2 MB code, 2 MB data), interfaces 1st interface MPI/DP 12 Mbit/s, (X1), 2nd interface Ethernet/PROFINET (X5) 3rd interface IF 964-DP plug-in (IF1)

cpu414f 3pn dp144

Failsafe CPU for the medium performance range with PROFINET functionality

  • RAM 4 MB

  • MPI/PROFIBUS DP-Master-Interface

  • pluggable PROFIBUS DP-Interface

  • PROFINET Interface with 2 ports

  • Memory Card slot

SIMATIC S7-400 CPU 416F-2

6ES7416-2FP07-0AB0

SIMATIC S7-400, CPU 416F-2, Central processing unit with: Work memory 8 MB, (4 MB code, 4 MB data), 1st interface MPI/DP 12 Mbit/s, 2nd interface PROFIBUS DP,

cpu416f 2 v144

Failsafe entry CPU for the upper performance range

  • RAM 5,6 MB

  • MPI/PROFIBUS DP-Master-Interface

  • additional PROFIBUS DP-Interface

  • Memory Card slot

SIMATIC S7-400 CPU 416F-3PN/DP

6ES7416-3FS07-0AB0

SIMATIC S7-400, CPU416F-3 PN/DP Central processing unit with: Work memory 16 MB, (8 MB code, 8 MB data), interfaces 1st interface MPI/DP 12 Mbit/s, (X1), 2nd interface Ethernet/PROFINET (X5) 3rd interface IF 964-DP plug-in (IF1)

cpu

Standard CPU for the upper performance range with PROFINET functionality

  • RAM 11,2 MB

  • MPI/PROFIBUS DP-Master-Interface

  • additional PROFIBUS DP-Interface

  • additional PROFINET Interface

  • Slot for additional IF-Module

  • Memory Card slot

Area of application

  • Automotive industry

  • General mechanical engineering

  • Special-purpose machine manufacturing

  • Series machine manufacturing, OEM

  • Plastics processing

  • Packaging industry

  • Food, beverages and tobacco industries

Benefits

Reduction of stock-keeping by saving components

  • One controller for standard and safety automation
    - Coexistence of standard and safety programs on one controller possible

  • One PROFIBUS or PROFINET transmitting medium for standard and safety communication to SIL 3/Category 4
    - One distributed I/O configuration with standard and safety I/O modules


Fast system configuration and commissioning

  • Better system integration
    - Uniform engineering for standard and safety control component
    - Use of existing PROFIBUS or PROFINET transmitting medium even for safety
    communication
    - Simple expansion of existing PROFIBUS architectures about PROFINET, p.ex. via IE/PB-
    Link (SIMATIC NET)

 

More flexibility

  • The logic of the safety functions is software-based rather than hard-wired
    - More easily modified, expanded and documented
    - Implementation of complex safety functions


Faster reproducibility

  • In contrast to the hardware solution, the software solution can be easily reproduced

  • Approved, certified solutions can often be used as self-contained blocks


Better retent of plant availability

  • Early fault detection thanks to better diagnostic functions


Investment security

  • Easy migration from PROFIBUS to PROFINET

safetygrafik en

Design and functions

Because of its performance power, the safety SIMATIC S7-400F CPU is predestined for meeting the demands of the highest performance range. Both standard and safety-relevant tasks can be performed with only one CPU. Multiprocessor operation is also possible.
The SIMATIC S7-400F CPUs can be expanded in distributed configurations with the safety I/O modules of the ET 200S, ET 200M, ET 200pro (IP67) or the safety digital block peripheral device ET 200eco (IP67).
The F-modules can be connected by the integrated interfaces or by communication processors (CPs).