Signal modules are the interface of SIMATIC S7-300 to the process. A host of different digital and analog modules provide exactly the inputs/outputs required for each task.
Digital and analog modules differ as regards the number of channels, voltage and current ranges, electrical isolation, diagnostics and alarm functions, etc.
Digital input | Analog input | ||||||
Module | Voltage range | Number of channels | Module | Measuring range | Resolution | Number of channels | |
SM 321 | 24 VDC | 16, 32 | SM 331 | Voltage | Up to 16 bits | 2, 8 | |
SM 321 | 48-125 V DC | 16 | SM 331 | Current (also HART) |
Up to 16 bits | 2, 8 | |
SM 321 | 24/48 VUC | 16 | SM 331 | Resistance | Up to 16 bits | 1, 4, 8 | |
SM 321 | 120/230 V DC | 8, 16, 32 | SM 331 | Thermocouple elements | Up to 16 bits | 2, 8 | |
SM 331 | Resistance The | Up to 16 bits | 1, 4, 8 |
Digital inputs/out | Analog input/output | ||||||
Module | Voltage range | Number of channels | Module | Measuring range | Resolution | Number of channels | |
SM 323 | 24 VDC | 8 or 16 DI and DO | SM 334 | Voltage | Up to 13 bits | 2, 4 | |
SM 327 | 24 V DC | 8 DI and 8 DX (parameterized as input or output) | SM 334 | Current (also HART) |
8 bits | 4 | |
SM 334 | Resistance | 13 bits | 4 | ||||
SM 334 | Resistance thermocouple | 15 bits | 4 | ||||
SM 335 | Voltage | 14 bits | 4 | ||||
SM 335 | Current | 14 bits | 4 |
Digital output | Analog output | |||||||
Module | Voltage range | Current range | Number of channels | Module | Measuring range | Resolution | Number of channels | |
SM 322 | 24 VDC | 0.5A | 8, 16 | SM 332 | Voltage | Up to 16 bits | 2, 4, 8 | |
SM 322 | 24 V DC | 2A | 8 | SM 332 | Current (also HART) |
Up to 16 bits | 2, 4, 8 | |
SM 322 | 48-125 V DAC | 1.5A | 8 | |||||
SM 322 | 120/130 V AC | 1A | 8, 16, 32 | |||||
SM 322 | 120/130 VAC | 2A | 8 | |||||
SM 322 | UC (relay) | 0.5A-5A | 8, 16 | |||||
Point-to-Point link via communications processors (CPs) is an extremely powerful and low cost alternative to bus-systems. The advantage of point-to-point links over bus systems is especially pronounced when only a few (RS485) devices are to be connected to the SIMATIC S7.
The CPs can also economically connect third party systems to the SIMATIC S7. Thanks to the great flexibility of the CPs different physical transmission media, speeds or even customized transmission protocols can be implemented.
The configuring data are stored in a system data block stored in the CPU. When modules are replaced, the new module is therefore immediately ready for use.
Technical data Point-to-Point Link |
||
Application | Low-cost entry version | Powerful computer conncetion, Loadable protocols |
Transmision rate | Low (19200 bit/s) | High (76800 bit/s) |
Loadable protocols | MODBUS master (6ES7340-1AA.), MODBUS slave (6ES7340-1AB.), Data highway (6ES7340-1AE.) |
|
Module | CP 340 | CP 341 |
Order No. Group: 6ES7 | 340-1. | 341-1. |
Physical transmission media | ||
RS 232C (V.24) | CP 340-1A | CP 341-1A |
20 mA (TTY) | CP 340-1B | CP 341-1B |
RS 422/485 (X.27) | CP 340-1C | CP 341-1C |
Integrated transmission protocols | ||
ACII | ■ | ■ |
Printer driver | ■ | ■ |
3964 (R) | ■ | ■ |
RK 512 | ■ |
Function m,odulesc are intelligent modules that independently
execute the technoogical tasks and thus reduce the load on the
CPU. They are used when a high level of accuracy and dyna,ic
response is required.
Function modules | ||
Tchnological function | Channels / Axes | Modue |
Counting, measuring, proportioning position detection (incremental) | 1 | FM350-1 |
Counting, measuring, proportining | 8 | FM 350-2 3) |
Cam controls | 1 | FM 352 |
High-speed dinary logic operations | 1 | FM 352- |
PID control (continuous) | 4 | FM 355C |
PID control (step/impulse) | 4 | FM 355S |
Temperature control (continuous) | 4 | FM 355-2C |
Temperature control (step/impulse) | 4 | FM 355-2S |
Positioning (rapid travers/creep feed) | 2 | FM 351 |
Position detection (SSI) | 3 | FSM 338 |
Positioning (with stepper drives) | 1 | FM 353 |
Positioning (with servo drives) | 1 | FM 354 |
Positioning, path control, interpolation, synchronization | 4 | FM 357-2 |
Isochronous connection of drives via PROFIBUS | 4 | IM 174 |
Commnuication processors are used for connecting S7-300
to the different dus systems / communication networks as well
for point-to-point link.
Communcations processors | |
Bus system /communication network | Module |
AS-Interface (mater) 2) | CP 343-2 CP343-2 P |
PROFIBUS DP 2) | CP 342-5 |
CP342-5 FO (for fiber-optic conductors) |
|
PROFIBUS FMS 2) | CP 343-5 |
PROFINET / Industrial Ethernet 2) | CP 343-1 Lean |
CP 343-1 | |
CP 343-1 Advanced (with IT functionnality) |
|
Point-to-point link | CP 340 4) CP 341 4) |
WAN | TIM 3V-IE TIM 3V-IE Advanced |
Technollogy CPU | CPU 315T-2 DP | CPU 317T-2 DP |
Dimensions | 160 x125 x 130 | 160 x 125 x 130 |
Required front connector | 1 x 40-pin | 1 x 40-pin |
Order No. group: 6ES7 | 315-6TG. | 317-6TJ. |
Momory | ||
RAM | 128 KB | 512 |
Instructions | 42 K | 170 K |
Processing times | ||
Bit memory | 0,1 µs | 0,05 µs |
Word operation/fixed-point operation/floating-point operations | 0,2/2/3 µs | 0,2/0,2/1 µs |
Bit memories/timers/counters | ||
Bit memory | 4096 bytes | 4096 bytes |
S7 timers/S7 counters | 256/256 | 512/512 |
IEC timers/IEC counters | ■ | ■ |
Address areas | ||
I/O address area | 2048/2048 bytes | 8192/8192 bytes |
Process I/O image | 128/128 byte | 256/256 bytes |
Digital channels (central) | 256 | 256 |
Analog channels (central) | 64 | 64 |
DP interface | ||
Integrated I/O | ■/■ | ■/■ |
DP slave | ■ | ■ |
Integrated I/O | ||
Digital inputs | 4 x 24 V DC; for BERO evaluation, for example | |
Digital outputs | 8 x 24 V DC; for high-speed cam switching functions | |
Integrated functions | Gearbox synchronism and curve synchronism Travel to fixed stop Registration mark correction via measuring probe Path-or time-dependent cam switching Controlled positioning |
Extensive reverse engineering service for obsolete controls
Complete electronic and instrumentation maintenance service for all plants and machines