The fail-safe SIMATIC S7-1500 CPUs are equipped with a large program and data memory for complex standard and fail-safe applications. They can be used as PROFINET I/O controller or as distributed intelligence (PROFINET I-device).
The process signals including safe signals can be recorded either centrally by signal modules or distributed via PROFINET.
The integrated PROFINET I/O interface is designed as a switch so that a line topology can be set up in the plant. The additionally integrated PROFINET I/O interface (as of CPU1516F-3) with separate IP address can be used for network separation, for example. Additional PROFINET/PROFIBUS interfaces can be added using communications modules. These also support PROFIsafe and thus allow the connection of even more fail-safe devices.
The SIMATIC S7-1500 fail-safe controllers are certified according to EN 61508 (2010 version) for functional safety and are suitable for use in safety-related applications up to SIL 3 according to
IEC 62061 and PL e according to ISO 13849. Additional password protection for F-configuration
and F-program is set up for IT security.
Failsafe CPUs | |
---|---|
CPU 1511F-1 PN: the entry-level CPU for medium fail-safe and standard applications |
|
CPU 1511F-1 PN: the entry-level CPU for standard and fail-safe applications with medium requirements for processing performance and reaction speeds in discrete manufacturing technology. The CPU 1511-1 PN can be used as PROFINET I/O controller or as distributed intelligence (PROFINET I-device). • Fail-safe CPU with display |
|
Order Information |
Article No. |
CPU 1511F-1PN |
|
CPU 1513F-1 PN for medium fail-safe and standard applications |
|
The CPU 1513F-1 PN is the CPU with medium program and data memory for standard and fail-safe applications which contain distributed automation structures in addition to centralized I/O. It can be used as PROFINET I/O controller or as distributed intelligence (PROFINET I-device). • Fail-safe CPU with display |
|
Order Information |
Article No. |
CPU 1513F-1 PN |
|
CPU 1515F-2 PN for medium to large fail-safe and standard applications |
|
CPU 1515F-2 PN for applications with medium/high requirements for program scope and processing speed, for distributed setup via PROFINET IO with PROFIsafe. • Fail-safe CPU with display |
|
Order Information |
Article No. |
CPU 1515F-2 PN |
|
CPU 1516F-3 PN/DP for exceptionally demanding fail-safe and standard applications and additional communication tasks |
|
CPU 1516F-3 PN/DP for applications with medium/high requirements for program scope and processing speed, for distributed setup via PROFINET I/O and PROFIBUS DP with PROFIsafe. • Fail-safe CPU with display |
|
Order Information |
Article No. |
CPU 1516F-3 PN/DP |
|
CPU 1517F-3 PN/DP for most sophisticated fail-safe and standard applications as well as processing speed |
|
CPU 1517F-3 PN/DP for applications with very high requirements for program scope and processing speed, for distributed setup via PROFINET I/O and PROFIBUS DP with PROFIsafe. The additional integrated PROFINET interfaces with separate IP address can be used for network separation for example. • Fail-safe CPU with display |
|
Order Information |
Article No. |
CPU 1517-3 PN/DP |
|
CPU 1518F-4 PN/DP for high-performance fail-safe and standard applications and shortest reaction times |
|
CPU 1518F-4 PN/DP for applications with high requirements for program scope and processing speed, for distributed setup via PROFINET I/O and PROFIBUS DP with PROFIsafe. The additional integrated PROFINET interfaces with separate IP address can be used for network separation for example. • Fail-safe CPU with display |
|
Order Information |
Article No. |
CPU 1518F-4 PN/DP |
|
CPU 1518F-4 PN/DP ODK for standard and failsafe application with high demand on the program scope and processing speed for decentral structure via PROFINET I/O and PROFIBUS DP with PROFIsafe • failsafe CPU with display |
|
Order Information |
Article No. |
CPU 1518-4F PN/DP ODK |