For use within explosive plants

Description

In many branches there exist explosive environments in manufacturing and following processes.

To assure a preferably high level of safety in these areas, there exist conditions in terms of laws, orders and norms.

For the use in these areas, there are Ex modules that are endorsed intrinsically-safe sensors and actuators being in zone 1 or 2 of explosive plants.

Area of application

The Ex modules are available to the automation particularly of chemical plants as appropriate operating supplies. They are applicable for applications in the measurement-, control- and regulation technology.

Areas of application:

  • Chemical/petrochemical industry

  • Gas industry 

  • Offshore industry

  • Transportation (e.g. tankers) 

  • Automotive engineering (e.g. at varnishing) 

  • Energy supply, energy distribution etc.

  • Generating plants

  • Special engineering (e.g. printing machines, cleaning machines)


Benefit

The igniting protection type intrinsically-safe offers following advantages to the user:

  • Easy interchangeability of intrinsically-safe  equipment during the business

  • Easy measurement and calibration of the measuring section during the business

  • Working in intrinsically-safe  energized loops without stop of the plant

  • No complex case execution (e.g. compression-proof encapsulation) necessary

  • Linking of intrinsically-safe equipment of different manufacturers possible

  • Approved igniting protection type in chemical industry


Design and functions

The main function of the analog Ex modules is the separation of the intrinsically-safe loops of the Ex field and the non intrinsically-safe internal loops of the automation plant.
The Ex analogl input modules transform the analog signals of the intrinsically-safe equipment in digital values for the following working.

The Ex analog output modules transform the digital signals of the automation plant in analog signals being necessary for the process.
Ex analog input/output modules are “appropriate electrical eqipment” of the igniting protection type intrinsically-safe (term [EEx ib] IIC according to DIN EN 50020). You get next to intrinsically-safe ones also non intrinsically-safe loops.

  • Same systems engineering as the other modules of S7-300

  • Galvanic separation of the module

  • Confusion safety through coding

  • Supply of the sensors and actuators through the module

  • Direct wiring of the inputs and outputs of the modules without a separating switch amplifier or transmitter feed unit

  • Different wiring of the software possible

  • Diagnosis capable modules

  • Reduced  planning, installation and documentation effort 

  • Operation also with ET 200M possible with connection to all SIMATIC automation systems and as norm slave to all PROFIBUS DP networks.


Technical specifications

Term

Analog input

Analog input 

Analog output 

Channels

4 AI in 4 channel groups

8AI in 4 channel groups, 8x thermocouples; 4x RTD-thermoresistors

4 AO in 4 channel groups 

Certificates, admissions, norms

     

(igniting protection type according to EN 50020 (CENELEC)

[EEx lib] IIC

[EEx lib] IIC

[EEx lib] IIC

igniting protection type according to FM

Class I, Division 2, Group A, B, C, D T4 Class I, Zone 2, Group IIC T4

Class I, Division 2, Group A, B, C, D T4 Class I, Zone 2, Group IIC T4

Class I, Division 2, Group A, B, C, D T4
Class I, Zone 2, Group IIC T4

Test number PTB

Ex-96.D.2092X

Ex-96.D.2108X 

Ex-96.D.2026X

Term 

Analog input

Analog input  

Channels 

2 AI in 2 channel groups

2 AO in 2 channel groups

igniting protection type according to EN 50020 (CENELEC)

II3 (2) GEEx nA [lib] IIC T4

II3 (2) GEEx nA [lib] IIC T4

igniting protection type according to FM

Class I, Division 2, Group A, B, C, D T4Class I, Zone 2, Group IIC T4

Class I, Division 2, Group A, B, C, D T4Class I, Zone 2, Group IIC T4

Test number PTB 

KEMA 97ATEX3039 X

KEMA 97ATEX2359 X 


 

Automotive Industry

The businesses of C&M Engineering provide unique solutions that improve automaker productivity.

 

Food Industry

Food industry applications endure unrelenting production demands that place components under unique operating conditions. Learn more about the innovative solutions from C&M Engineering for the food industry.

Metal Industry

C&M Engineering offers time tested solutions that deliver measurable improvements to production efficiency and profitability for the metals industry.

Mining, Minerals & Cement

Optimize your machines for the highest efficiency and up-time. C&M Engineering gives the best line up of solutions for all your cement and bulk handling needs.

Oil & Gas Industry

The oil and gas industry has strict requirements for safety and reliability. C&M Engineering offers a wide range of solutions that deliver measurable improvements to production safety, efficiency and profitability.

 

Packaging Industry

For the packaging industry, C&M Engineering offers solutions that can improve product quality and yield while reducing cost, waste and downtime.

 

 

 

 

 

 

Fibers & Textile Industry

As an expert in the textiles industry, we offer a range of solutions specificallyfor fiber and textiles manufacturing that can improve your operation at every point.

Beverage Industry

With high-speeds and wet conditions, beverage production applications can be hard on components. C&M Engin- eering offers a wide range of solutions to keep beverage production lines moving.