Technical specifications Standard CPUs

SIMATIC S7-300

CPU CPU 312 CPU 314 1)
CPU 315-2 DP 1)
CPU 315-2 PN/DP 1) CPU 317-2 DP CPU 317-2 PN/DP 1) CPU 319-3 PN/DP
Dimension (mm)
40 x 125 x 130 40 x 125 x 130 80 x 125 x 130 80 x 125 x 130 120 x 125 x 130
Order No. group: 6ES7 312-1AE. 314-1AG. 315-2AG. 315-2EH. 317-2AJ. 317-2EK. 318-EL.
Memory
RAM 32 KB 96 KB 128 KB 256 KB 512 KB 1 MB 1.4 MB
Instructions 10 K 32 K 42 K 84 K 170 K 340 K 470 K
Processing times
Bit operation 0.2 µs 0.1 µs 0.1 µs 0.05 µs 0.01 µs
Word operation 0.4 µs 0.2 µs 0.2µs 0.2µs 0.02 µs
Fixed-point operation 5 µs 2 µs 2 µs 0.2 µs 0.02 µs
Floating-point operation 6 µs 3 µs 3 µs 1 µs 0.04 µs
Bit memories/times/counters
Bit memory 128 bytes 256 bytes 2048 bytes 4096 bytes 8192/8192
S7 timers/counters 128/128 256/256 256/256 512/512 2048/2048
IEC timers/ counters
Address areas
I/O (bytes) 1024/1024 1024/1024 2048/2048 8192/8192 8192/8192 8192/8192
I/O process image (bytes) 128/128 128/128 128/128 256/256 2048/2048 2048/2048
Digital channels (central) 256 1024 1024 1024 1024 1024
Analog channels (central) 64 256 256 256   256
DP interfaces
DP master system internal / CP 342-5 -/ ■/■ ■/■ ■/■ ■/■
DP slaves  
PROFINET interface
PROFINET CBA    
PROFINET IO    
TCP/IP    
UDP    
ISO-on-TCP (RFC 1006)     n
Web server     n

 

 

  • Overview
  • Documentation

Features

  • Built-in GuardPLC™ 100 Mbps Ethernet network connectivity
  • Built-in two-port Ethernet switch makes it easy to connect I/O modules to the GuardPLC controller
  • Works with GuardPLC 1600 and GuardPLC 1800 safety controllers
  • GuardPLC Hand-held Terminal speeds commissioning of new or replacement GuardPLC I/O modules

Products

1753 GuardPLC Digital I/O Blocks

  • 24V DC safety I/O circuits
  • Up to 28 points per block
  • Input, output, relay and combination blocks available

1753 GuardPLC Analog I/O Blocks

  • Combination I/O block
  • Includes eight safety inputs and four standard outputs

Certifications

  • c-UL-us, CE, C-Tick, TÜV-certified up to SIL 3, Cat. 4, PLe
 