Fail-safe S7-300 CPU

Description

The fail-safe SIMATIC controllers are used to guarantee the functional safety of machines or plants. They satisfy maximum safety requirements and comply with the relevant standards:
EN 954-1 up to Cat. 4, IEC 62061 up to SIL 3 and EN ISO 13849-1 up to PL e.
The simultaneous processing of the standard and the safety program means that only one CPU is required to handle both tasks.

Area of application

  • Automobile industry

  • General mechanical engineering

  • Building of special machines

  • Series mechanical engineering, OEM

  • Plastics processing

  • Packaging industry

  • Food- and Beverageindustry

Benefits

Reduction of stock-keeping by saving components

  •  One controller for standard and safety automation
    - Coexistence of standard and safety programs on one controller possible

  • One PROFIBUS or PROFINET transmitting medium for standard and safety communication to SIL 3/Category 4
    - One distributed I/O configuration with standard and safety I/O modules


Fast system configuration and commissioning

  • Better system integration     
    - Uniform engineering for standard and safety control component
    - Use of existing PROFIBUS or PROFINET transmitting medium even for safety  
      communication
    - Simple expansion of existing PROFIBUS archtictures about PROFINET, p.ex. via IE/PB-Link
      (SIMATIC NET)


More flexibility   

  • The logic of the safety functions is software-based rather than hard-wired
     
    - More easily modified, expanded and documented
    - Implementation of complex safety functions


Faster reproducibility

  • In contrast to the hardware solution, the software solution can be easily reproduced

  • Approved, certified solutions can often be used as self-contained blocks


Better retent of plant availability

  • Early fault detection thanks to better diagnostic functions

Investment security  

  • Easy migration from PROFIBUS to PROFINET

Standard and safety automation – divided into two systems – integrated in one system

Area of application

Because of their power and compactness, the safety SIMATIC S7-300F CPUs are ideal for meeting the demands of the mid to upper performance range. Both standard and safety-relevant tasks can be performed with only one CPU.

The SIMATIC S7-300F CPUs can be expanded centrally with the safety modules for the ET 200M I/O. Distributed expansion is possible using the safety ET 200S I/O modules, the ET 200M I/O modules, the ET 200pro (IP67) I/O modules or the safety digital block peripheral device ET 200eco (IP67).

Communication works depending on the CPU optional via MPI, PROFIBUS or PROFINET Interface.

SIMATIC S7-300 CPU 315F-2 DP

6ES7315-6FF04-0AB0

SIMATIC S7-300, CPU 315F-2DP Fail-safe module with MPI Integr. power supply 24 V DC, Work memory 384 KB, 40 mm width, 2nd interface DP master/slave Micro Memory Card required

CPU 315F-2 DP

The failsafe CPU with medium to large program memory and quantity framework for the use, if required, of SIMATIC Engineering Tools

  • High processing performance in binary and floating-point arithmetic

  • Distributed fail-safe I/O modules can be connected via the integral PROFIBUS DP interface (PROFIsafe)

SIMATIC S7-300 CPU 315F-2 PN/DP

6ES7315-2FJ14-0AB0

SIMATIC S7-300 CPU315F-2 PN/DP, Central processing unit with 512 KB work memory, 1st interface MPI/DP 12 Mbit/s, 2nd interface Ethernet PROFINET, with 2-port switch, Micro Memory Card required

CPU 315F-2 PN/DP

The failsafe CPU with a medium program memory and quantity framework

  • 40 mm width   

  • Integral PROFINET interface with 2 Ports for line topologies

  • High processing performance in binary and floating-point arithmetic

  • Fail-safe I/O modules in distributed stations can be connected through the integrated PROFINET interface (PROFIsafe) and/or through the integrated PROFIBUS DP interface (PROFIsafe)  

  • Component based Automation (CBA) on PROFINET

  • PROFINET-proxy for intelligent devices on PROFIBUS DPin Component Based Automation (CBA)

SIMATIC S7-300 CPU 317F-2 DP

6ES7317-6FF04-0AB0

SIMATIC S7-300, CPU 317F-2DP, Central processing unit with 1.5 MB work memory, 1st interface MPI/DP 12 Mbit/s, 2nd interface DP master/slave Micro Memory Card required Can be used with software package S7 Distributed Safety V5.2 SP1 or higher

CPU 317F-2 DP

The failsafe CPU with a large program memory and quantity framework for demanding requirements    

  • Distributed fail-safe I/O modules can be connected via the integral PROFIBUS DP interfaces (PROFIsafe)  


Product announcement:
The PROFIBUS CPU317 is also available as a fail-safe Technology Controller.
For more information see:

SIMATIC S7-300 CPU 317F-2 PN/DP

6ES7317-2FK14-0AB0

SIMATIC S7-300 CPU317F-2 PN/DP, Central processing unit with 1.5 MB work memory, 1st interface MPI/DP 12 Mbit/s, 2nd interface Ethernet PROFINET, with 2-port switch, Micro Memory Card required

CPU 317F-2 PN/DP

The failsafe CPU with a large program memory and quantity framework for demanding requirements

  • 40 mm width      

  • Integral PROFINET interface with 2 Ports for line topologies

  • Fail-safe I/O modules in distributed stations can be connected through the integrated PROFINET interface (PROFIsafe) and/or through the integrated PROFIBUS DP interface (PROFIsafe)     

  • Component based Automation (CBA) on PROFINET

  • PROFINET proxy for intelligent devices on PROFIBUS DPin Component Based Automation (CBA)

SIMATIC S7-300 CPU 319F-3 PN/DP

6ES7318-3FL01-0AB0

SIMATIC S7-300 CPU319F-3 PN/DP, Central processing unit with 2.5 MB work memory, 1st interface MPI/DP 12 Mbit/s, 2nd interface DP master/slave 3rd interface Ethernet PROFINET, Micro Memory Card required

CPU 319F-3 PN/DP

The failsafe CPU with highest processing performance, enlarged quantity framework and enhanced communication possibilities.

  • Integral PROFINET interface with 2 Ports for line topologies

  • Fail-safe I/O modules in distributed stations can be connected through the integrated PROFINET interface (PROFIsafe) and/or through the integrated PROFIBUS DP interface (PROFIsafe)   

  • Component based Automation (CBA) on PROFINET

  • PROFINET proxy for intelligent devices on PROFIBUS DPin Component Based Automation (CBA)

Technical data

 
 

 

  • Overview
  • Products
  • Documentation

Features

  • Five levels of control available, providing a wide variety of features to suit most applications
  • Offers similar functionality as traditional SLCs and PLCs, only in a smaller, packaged form factor
  • Compatible with our PanelView™ Component graphic terminals
  • Shares common RSLogix™ 500 programming software and RSLogix Micro programming software, providing an instruction set that is common to the MicroLogix™ and SLC™ 500 controller families

Products

  • 1761 MicroLogix 1000 Controllers
  • 1763 MicroLogix 1100 Controllers
  • 1762 MicroLogix 1200 Controllers
  • 1766 MicroLogix 1400 Controllers
  • 1764 MicroLogix 1500 Controllers
  • 1761 Communication Interfaces
  • 1762 MicroLogix Expansion I/O
  • 1769 Compact I/O™

MicroLogix 1000 Control System

Bulletin 1761 MicroLogix™ 1000 Controllers are the most compact of the MicroLogix family. This controller fits a wide variety of applications up to 32 I/O points, while using a fraction of the space of a full-size controller. It contains embedded analog I/O, providing compact and cost-effective analog performance.

MicroLogix 1100 Control System

Bulletin 1763 MicroLogix™ 1100 Controllers add embedded EtherNet/IP™, on-line editing and an LCD to the MicroLogix family. The built-in LCD shows controller status, I/O status and simple operator messages. With 2 analog inputs, 10 digital inputs and 6 digital outputs, the MicroLogix 1100 controller can handle a wide variety of tasks.

MicroLogix 1200 Control System

Bulletin 1762 MicroLogix™ 1200 Controllers are small enough to fit in tight spaces and powerful enough to accommodate a broad range of applications. Our controller is available in 24-point and 40-point versions. You can expand the I/O count using rackless I/O modules. You can build larger control systems, achieve greater application flexibility, and expand your system at a lower cost and with reduced parts inventory. A field-upgradeable flash operating system keeps you be up-to-date with the latest features.

MicroLogix 1400 Control System

Bulletin 1766 MicroLogix™ 1400 Controllers build upon critical MicroLogix 1100 features: EtherNet/IP™, on-line editing and a built-in LCD. These controllers feature a higher I/O count, faster high-speed counter, pulse train output, enhanced network capabilities and backlight on the LCD. Controllers without embedded analog I/O points provide 32 digital I/O points, while analog versions offer 32 digital I/O points and 6 analog I/O points. You can expand all versions with up to seven 1762 expansion I/O modules.

MicroLogix 1500 Control System

Bulletin 1764 MicroLogix™ 1500 Controllers are the most expandable members of the MicroLogix family. Building upon the critical features of the MicroLogix 1200 controllers, this controller fits many applications that traditionally called for larger, more expensive controllers. With a processor, base unit with power supply and embedded I/O, this controller packs the best features of a modular system into a low-cost, small footprint.

MicroLogix Expansion I/O

Bulletin 1762 MicroLogix™ Expansion I/O modules extend the capabilities of the MicroLogix 1100, 1200, and 1400 controllers by maximizing flexibility of the I/O count and type. The modular, rackless design enhances cost savings and reduces replacement parts inventory. Modules can be either DIN rail or panel mounted.

Compact I/O

Bulletin 1769 Compact I/O™ modules can be used as local and distributed I/O for a CompactLogix™ or MicroLogix™ 1500 controller. Select from a variety of digital, analog, and specialty modules. The 16- and 32-point modules provide high-density I/O in a small package. A built-in removable terminal block provides connections to I/O sensors and actuators. You can route the  I/O wiring from beneath the module to the I/O terminals.

MicroLogix Communications

Bulletin 1761 Communication Interfaces and Bulletin 1769 DeviceNet™ Scanner Module support your MicroLogix™ controller systems with a variety of features. Any DH-485 compatible device that has an RS-232 port can access any other DH-485 network with these products. Connect to Ethernet networks and upload programs, download programs, communicate between controllers and leverage web server functionality. Program and monitor your MicroLogix system over the DeviceNet network. Upload, download, and monitor programs through the DeviceNet scanner.

Frequently Viewed Publications

TitleNumberLanguage
MicroLogix Family Brochure 1761-BR006
MicroLogix 1100 Product Profile 1763-PP001
MicroLogix 1400 Product Profile 1766-PP001
MicroLogix Programmable Controllers Family Selection Guide 1761-SG001
MicroLogix 1000 Programmable Controllers User Manual 1761-UM003
MicroLogix 1100 Programmable Controllers User Manual 1763-UM001
MicroLogix 1200 Programmable Controllers User Manual 1762-UM001
MicroLogix 1400 Programmable Controllers User Manual 1766-UM001
MicroLogix 1500 Programmable Controllers User Manual 1764-UM001