A wide lineup in FX series offers you many choices to fit to your budget and application.
You are sure to find a model that fulfills your needs.
Powered extension units are I/O extension devices with built-in power supply.
Like with the main unit, various I/O devices and special devices can be connected after a powered extension unit.
Model | Total number of points |
Number of input/output points Input/output type |
Applicable FX PLC | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Input | Output | FX 3S |
FX 3G |
FX 3U |
FX 3GC |
FX 3UC |
||||||||||
AC Power Type | ||||||||||||||||
FX2N-32ER | 32 points | 16 points | 24 V DC (sink) |
16 points | Relay | × | ○ | ○ | × | × | ||||||
FX2N-32ER-ES/UL | 24 V DC (sink/ source) |
|||||||||||||||
FX2N-32ES | 24 V DC (sink) |
Triac | ||||||||||||||
FX2N-32ET | 24 V DC (sink) |
Transistor (sink) |
||||||||||||||
FX2N-32ET-ESS/UL | 24 V DC (sink/ source) |
Transistor (source) |
||||||||||||||
FX2N-48ER | 48 points | 24 points | 24 V DC (sink) |
24 points | Relay | × | ○ | ○ | × | × | ||||||
FX2N-48ER-ES/UL | DC24V (sink/ source) |
|||||||||||||||
FX2N-48ET | 24 V DC (sink) |
Transistor (sink) |
||||||||||||||
FX2N-48ET-ESS/UL | 24 V DC (sink/ source) |
Transistor (source) |
||||||||||||||
FX2N-48ER-UA1/UL | 48 points | 24 points | 100 V AC | 24 points | Relay | × | ○ | ○ | × | × | ||||||
DC Power Type | ||||||||||||||||
FX2N-48ER-D | 48 points | 24 points | 24 V DC (sink) |
24 points | Relay | × | ○ | ○ | × | × | ||||||
FX2N-48ER-DS | 24 V DC (sink/ source) |
|||||||||||||||
FX2N-48ET-D | 24 V DC (sink) |
Transistor (sink) |
||||||||||||||
FX2N-48ET-DSS | 24 V DC (sink/ source) |
Transistor (source) |
Regarding connection cable
A connection cable (length: 55mm), used to connect to the the right side of the device in front of the powered extension unit, is included with the powered extension unit.
To extend the distance of the connection, please use the optional "extension cable".
The expansion board is designed to add the input and output terminal whose points are small to FX3S or FX3G PLCs. The board can be built in the PLC.
Model | Total number of points |
Number of input/output points Input/output type |
Applicable FX PLC | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Input | Output | FX 3S |
FX 3G |
FX 3U |
FX 3GC |
FX 3UC |
||||||||||
FX3G-4EX-BD | 4 points |
4 points |
24 V DC (sink/ source) |
- | - | *1 ○ Max. 1 unit |
*2 ○ Max. 1 unit |
× | × | × | ||||||
FX3G-2EYT-BD | 2 points |
- | - | 2 points |
Transistor (sink/ source) |
*1 ○ Max. 1 unit |
*2 ○ Max. 1 unit |
× | × | × |
*1: Supported by FX3S ver.1.10 and later.
*2: Supported by FX3G ver.2.20 and later.
Extension block is an I/O extension device that receives power from the main unit or powered extension unit.
It can be connected in 8 point or 16 point units. The connectable number of points is determined by each main unit or powered extension unit
Model | Total number of points |
Number of input/output points Input/output type |
Applicable FX PLC | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Input | Output | FX 3S |
FX 3G |
FX 3U |
FX 3GC |
FX 3UC |
||||||||||
Input/output extension blocks | ||||||||||||||||
FX2N-8ER | 8 points | 4 points (8 devices are occupied.) |
24 V DC (sink) |
4 points (8 devices are occupied.) |
Relay | × | ○ | ○ | *1 *2 ○ |
*1 *2 ○ |
||||||
FX2N-8ER-ES/UL | DC24V (sink/ source) |
|||||||||||||||
FX2N-8EX | 8 points | 24 V DC (sink) |
- | - | ||||||||||||
FX2N-8EX-ES/UL | DC24V (sink/ source) |
|||||||||||||||
FX2N-8EX-UA1/UL | 100 V AC | |||||||||||||||
FX2N-16EX | 16 points | 16 points | 24 V DC (sink) |
× | ○ | ○ | *1 *2 ○ |
*1 *2 ○ |
||||||||
FX2N-16EX-ES/UL | 24 V DC (sink/ source) |
|||||||||||||||
FX2N-16EX-C Connector input |
24 V DC (sink) |
|||||||||||||||
FX2N-16EXL-C Connector input |
5 V DC | |||||||||||||||
Output extension blocks | ||||||||||||||||
FX2N-8EYR | 8 points | - | - | 8 points | Relay | × | ○ | ○ | *1 *2 ○ |
*1 *2 ○ |
||||||
FX2N-8EYR-ES/UL | ||||||||||||||||
FX2N-8EYR-S-ES/UL | Relay (8 points/common) |
|||||||||||||||
FX2N-8EYT | Transistor (sink) |
|||||||||||||||
FX2N-8EYT-H | ||||||||||||||||
FX2N-8EYT-ESS/UL | Transistor (source) |
|||||||||||||||
FX2N-16EYR | 16 points | 16 points | Relay | × | ○ | ○ | *1 *2 ○ |
*1 *2 ○ |
||||||||
FX2N-16EYR-ES/UL | ||||||||||||||||
FX2N-16EYS | Triac | |||||||||||||||
FX2N-16EYT | Transistor (sink) |
|||||||||||||||
FX2N-16EYT-ESS/UL | Transistor (source) |
|||||||||||||||
FX2N-16EYT-C Connector output |
Transistor (sink) |
*1 :For connection to FX3GC or FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.
*2 :Depending on the model name of the main unit, I/O extension device connection may or may not be allowed. For details, refer to the manual of the main unit.
Regarding connection cable
A connection cable, used to connect to the right side of the device in front of the extension block, is included with the extension block.
To extend the distance of the connection, please use the optional "extension cable (FX0N-30EC/FX0N-65EC)" and "connector conversion adapter (FX2N-CNV-BD)".
These I/O extension devices can be directly connected to FX1NC, FX3GC, FX2NC, FX3UC PLCs.
They can be compactly extended because connection cables are not needed.
Model | Total number of points |
Number of input/output points Input/output type |
Applicable FX PLC | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Input | Output | FX 3S |
FX 3G |
FX 3U |
FX 3GC |
FX 3UC |
||||||||||
Input extension blocks | ||||||||||||||||
FX2NC-16EX-T Terminal block input |
16 points | 16 points | 24 V DC (sink) |
- | - | × | × | × | * ○ |
* ○ |
||||||
FX2NC-16EX-T-DS Terminal block input |
DC24V (sink/ source) |
|||||||||||||||
FX2NC-16EX | DC24V (sink) |
|||||||||||||||
FX2NC-16EX-DS | DC24V (sink/ source) |
|||||||||||||||
FX2NC-16EX-D/UL | DC24V (sink) |
|||||||||||||||
FX2NC-32EX | 32 points | 32 points | 24 V DC (sink) |
|||||||||||||
FX2NC-32EX-DS | DC24V (sink/ source) |
|||||||||||||||
FX2NC-32EX-D/UL | DC24V (sink) |
|||||||||||||||
Output extension blocks | ||||||||||||||||
FX2NC-16EYR-T Terminal block Output |
16 points | - | - | 16 points | Relay | × | × | × | * ○ |
* ○ |
||||||
FX2NC-16EYR-T-DS Terminal block output |
||||||||||||||||
FX2NC-16EYT | Transistor (sink) |
|||||||||||||||
FX2NC-16EYT-DSS | Transistor (source) |
|||||||||||||||
FX2NC-16EYT-D/UL | Transistor (sink) |
|||||||||||||||
FX2NC-32EYT | 32 points | 32 points | Transistor (sink) |
|||||||||||||
FX2NC-32EYT-DSS | Transistor (source) |
|||||||||||||||
FX2NC-32EYT-D/UL | Transistor (sink) |
|||||||||||||||
Input/output extension blocks | ||||||||||||||||
FX2NC-64ET | 64 points | 32 points | 24 V DC (sink) |
32 points | Transistor (sink) |
× | × | × | * ○ |
* ○ |
*: Depending on the model name of the main unit, I/O extension device connection may or may not be allowed. For details, refer to the manual of the main unit
Model (Number of channels) |
Input specifications | Applicable FX PLC | |||||||||||
Item | Input voltage | Input current | FX 3S |
FX 3G |
FX 3U |
FX 3GC |
FX 3UC |
||||||
FX3G-2AD-BD (Input 2 ch) |
Input range |
0 to 10 V DC (Input resistance 198.7 kΩ) |
4 to 20 mA DC (Input resistance 250 Ω) |
*3 ○ Max. 1 unit |
*1*2 ○ Max. 2 units |
× | × | × | |||||
Resolution | 2.5 mV (10 V/4000) |
8 μA {(20 - 4 mA)/2000} |
|||||||||||
FX3G-1DA-BD (Output 1 ch) |
Output range |
0 to 10 V DC (External load resistance value 2 kΩ to 1 MΩ) |
4 to 20 mA DC (External load resistance value 500 Ω or less) |
*3 ○ Max. 1 unit |
*1*2 ○ Max. 2 units |
× | × | × | |||||
Resolution | 2.5 mV (10 V/4000) |
8 μA {(20 - 4 mA)/2000} |
*1: Supported by FX3G ver. 1.10 and later.
*2: FX3G 14pt, 24pt models: 1 board. 40pt, 60pt models: 2 boards.
*3: Function expansion board and FX3S-CNV-ADP cannot be used together.
Model (Number of channels) |
Input/output specifications | Applicable FX PLC | |||||||||||
Item | Input/output voltage | Input/output current | FX 3S |
FX 3G |
FX 3U |
FX 3GC |
FX 3UC |
||||||
FX3U-3A-ADP (Input 2 ch) (Output 1ch) |
Input range |
0 to 10 V DC (Input resistance 198.7 kΩ) |
4 to 20 mA DC (Input resistance 250 Ω) |
*7 ○ Max. 1 unit |
*1*6 ○ Max. 2 units |
*2 ○ Max. 4 units |
○ Max. 2 units |
*3 ○ Max. 4 units |
|||||
Output range |
0 to 10 V DC (External load resistance value 5 kΩ to 1 MΩ) |
4 to 20 mA DC (External load resistance value 500 Ω or less) |
|||||||||||
Resolution | [Input voltage] 2.5 mV (10 V/4000) [Output voltage] 2.5 mV (10 V/4000) |
[Input current] 5 μA (16 mA/3200) [Onput current] 4 μA (16 mA/4000) |
|||||||||||
FX2N-5A (Input 4 ch) (Output 1ch) |
Input range |
-100 to 100 mV DC -10 to 10 V DC (Input resistance 200 kΩ) |
-20 to 20 mA DC 4 to 20 mA DC (Input resistance 250 Ω) |
× | × | ○ Max. 8 units |
× | *4*5 ○ Max. 8 units |
|||||
Output range |
-10 to 10 V DC (External load resistance value 2 kΩ to 1 MΩ) |
0 to 20 mA DC, 4 to 20 mA DC (External load resistance value 500 Ω or less) |
|||||||||||
Resolution | 50 μV (at ±100 mV) 312.5 μV (at ±10 V) |
1.25 μA,10 μA ((depending on mode used)) |
*1: Supported by FX3G ver.1.20 and later. For connection to FX3G, FX3G-CNV-ADP is required.
*2: Supported by FX3U ver.2.61 and later. For connection to FX3U, function expansion board is required.
*3: Supported by FX3UC ver.2.61 and later. When connecting to FX3UC- 32MT-LT(-2), function expansion board is required.
*4: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC- 1PS-5V is required.
*5: FX3UC- 32MT-LT(-2): 7 units. FX3UC-**MT/D, FX3UC- **MT/DSS, FX3UC-16MR/D (S)-T: 8 units.
*6: FX3G 14 pt, 24 pt models: 1 board. 40 pt, 60 pt models: 2 boards.
*7: For connection to FX3S, FX3S-CNV-ADP is required.
Model (Number of channels) |
Input specifications | Applicable FX PLC | |||||||||||
Item | Input voltage | Input current | FX 3S |
FX 3G |
FX 3U |
FX 3GC |
FX 3UC |
||||||
FX3S-30MR/ES-2AD FX3S-30MT/ES-2AD FX3S-30MT/ESS-2AD (Input 2ch) |
Input range |
0 to 10 V DC (Input resistance 115.7 kΩ) |
- | - | - | - | - | - | |||||
Resolution | 10 mV (10 V/1000) |
- | |||||||||||
FX2N-2AD (Input 2 ch) |
Input range |
0 to 10 V DC, 0 to 5 V DC (Input resistance 200 kΩ) The input characteristic is the same for each channel. |
4 to 20 mA DC (Input resistance 250 Ω) The input characteristic is the same for each channel. |
× | × | ○ Max. 8 units |
× | *1*2 ○ Max. 8 units |
|||||
Resolution | 2.5 mV (10 V × 1/4000) 1.25 mV (5 V × 1/4000) |
4 μA ((20 - 4 mA) × 1/4000) |
|||||||||||
FX3U-4AD (Input 4ch) |
Input range |
-10 to 10 V DC (Input resistance 200 kΩ) |
-20 to 20 mA DC, 4 to 20 mA (Input resistance 250 Ω) |
× | × | ○ Max. 8 units |
× | *1*2 ○ Max. 8 units |
|||||
Resolution | 0.32 mV (20 V × 1/64000) |
1.25 μA (40 mA × 1/32000) |
|||||||||||
FX3U-4AD-ADP (Input 4ch) |
Input range |
0 to 10 V DC (Input resistance 194 kΩ) |
4 to 20 mA DC (Input resistance 250 Ω) |
*8 ○ Max. 1 unit |
*4*3 ○ Max. 2 units |
*5 ○ Max. 4 units |
○ Max. 2 units |
*5*6 ○ Max. 4 units |
|||||
Resolution | 2.5 mV (10 V/4000) |
10 μA (16 mA/1600) |
|||||||||||
FX3UC-4AD (Input 4ch) |
Input range |
-10 to 10 V DC (Input resistance 200 kΩ) |
4 to 20 mA DC, -20 to 20 mA DC (Input resistance 250 Ω) |
× | × | × | × | *7*2 ○ Max. 8 units |
|||||
Resolution | 0.32 mV (20 V × 1/64000) 2.50 mV (20 V × 1/8000) |
1.25 μA (40 mA × 1/32000) 5.0 μA (40 mA × 1/8000) |
|||||||||||
FX2N-8AD (Input 8 ch) |
Input range |
-10 to 10 V DC (Input resistance 200 kΩ) |
4 to 20 mA DC -20 to 20 mA DC (Input resistance 250 Ω) |
× | × | ○ Max. 8 units |
× | *1*2 ○ Max. 8 units |
|||||
Resolution | 0.63 mV (20 V × 1/32000) 2.50 mV (20 V × 1/8000) |
2.5 μA (40 mA × 1/16000) 2 μA (16 mA × 1/8000) 5.0 μA (40 mA × 1/8000) 4 μA (16 mA × 1/4000) |
*1: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC- 1PS-5V is required.
*2: FX3UC- 32MT-LT(-2): 7 units. FX3UC-**MT/D, FX3UC- **MT/DSS, FX3UC-16MR/D (S)-T: 8 units.
*3: FX3G 14pt, 24pt models: 1 board. 40pt, 60pt models: 2 boards.
*4: When connecting to FX3G, FX3G-CNV-ADP is required.
*5: When connecting to FX3U, function expansion board is required.
*6: FX3UC- 32MT-LT supported from version 1.20 or later.
*7: FX3UC- 32MT-LT supported from version 1.30 or later.
*8: When connecting to FX3S, FX3S-CNV-ADP is required.
Model (Number of channels) |
Output specifications | Applicable FX PLC | |||||||||||
Item | Output voltage | Output current | FX 3S |
FX 3G |
FX 3U |
FX 3GC |
FX 3UC |
||||||
FX2N-2DA (Output 2 ch) |
Output range |
0 to 10 V DC, 0 to 5 V DC (External load resistance value 2 kΩ to 1 MΩ) |
4 to 20 mA DC (External load resistance value 400 Ω or less) |
× | × | ○ Max. 8 units |
× | *1*2 ○ Max. 8 units |
|||||
Resolution | 2.5 mV (10 V × 1/4000) 1.25 mV (5 V × 1/4000) |
4 μA ((20 - 4) mA × 1/4000) |
|||||||||||
FX3U-4DA (Output 4 ch) |
Output range |
-10 to 10 V DC (External load resistance value 1 kΩ to 1 MΩ) |
0 to 20 mA DC 4 to 20 mA DC (External load resistance value 500 Ωor less) |
× | × | ○ Max. 8 units |
× | *1*2 ○ Max. 8 units |
|||||
Resolution | 0.32 mV (20 V × 1/64000) |
0.63 μA (20 mA × 1/32000) |
|||||||||||
FX3U-4DA-ADP (Output 4 ch) |
Output range |
0 to 10 V DC (External load resistance value 5 kΩ to 1 MΩ) |
4 to 20 mA DC (External load resistance value 500 Ω or less) |
*7 ○ Max. 1 unit |
*3*4 ○ Max. 2 units |
*5 ○ Max. 4 units |
○ Max. 2 units |
*5*6 ○ Max. 4 units |
|||||
Resolution | 2.5 mV (10 V/4000) |
4 μA (16 mA/4000) |
*1: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC- 1PS-5V is required.
*2: FX3UC- 32MT-LT(-2): 7 units. FX3UC-**MT/D, FX3UC- **MT/DSS, FX3UC-16MR/D (S)-T: 8 units.
*3: FX3G 14 pt, 24 pt models: 1 board. 40 pt, 60 pt models: 2 boards.
*4: When connecting to FX3G, FX3G-CNV-ADP is required.
*5: When connecting to FX3U, FX3UC-32MT-LT(-2), function expansion board is required.
*6: FX3UC- 32MT-LT supported from version 1.20 or later.
*7: When connecting to FX3S, FX3S-CNV-ADP is required.
Model (Number of channels) |
Type | Highest response frequency |
Hardware comparison output function |
2-phase counter edge count function |
Applicable FX PLC | |||||||||
FX 3S |
FX 3G |
FX 3U |
FX 3GC |
FX 3UC |
||||||||||
FX2N-1HC (1ch) |
1-phase 1-count |
Max. 50 kHz | ○ | - | × | × | ○ Max. 8 units |
× | *2*3 ○ Max. 8 units |
|||||
1-phase 2-count |
Max. 50 kHz | |||||||||||||
2-phase 2-count |
1 edge count: Max. 50 kHz 2 edge count: Max. 25 kHz 4 edge count: Max. 12.5 kHz |
○ | ||||||||||||
FX3U-2HC (2ch) |
1-phase 1-count |
Max. 200 kHz | ○ | - | × | × | ○ Max. 8 units |
× | *2 ○ Max. 4 units |
|||||
1-phase 2-count |
Max. 200 kHz | |||||||||||||
2-phase 2-count |
1 edge count: Max. 200 kHz 2 edge count: Max. 100 kHz 4 edge count: Max. 50 kHz |
○ | ||||||||||||
FX2NC-1HC (1ch) |
1-phase 1-count |
Max. 50 kHz | ○ | - | × | × | × | × | *3 ○ Max. 8 units |
|||||
1-phase 2-count |
Max. 50 kHz | |||||||||||||
2-phase 2-count |
1 edge count: Max. 50 kHz 2 edge count: Max. 25 kHz 4 edge count: Max. 12.5 kHz |
○ | ||||||||||||
FX3U-4HSX-ADP (4ch) |
1-phase 1-count |
Max. 200 kHz | × | ○ | × | × | *1 ○ Max. 2 units |
× | × | |||||
1-phase 2-count |
Max. 200 kHz | |||||||||||||
2-phase 2-count |
1 edge count: Max. 100 kHz 4 edge count: Max. 100 kHz |
*1: When used together with analog or communication adapters, function expansion board is required.
*2: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.
*3: FX3UC-32MT-LT(-2): 7 units. FX3UC-**MT/D,FX3UC-**MT/DSS,FX3UC-16MR/D(S)-T: 8 units.
Model | Number of controlled axis |
Maximum frequency |
Applicable FX PLC | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FX 3S |
FX 3G |
FX 3U |
FX 3GC |
FX 3UC |
|||||||||
FX3U-2HSY-ADP | Independent two axes | 200kHz | × | × | * ○ Max. 2 units |
× | × |
*: When used together with analog or communication adapters, function expansion board is required
Model | Number of controlled axis |
Maximum frequency |
Applicable FX PLC | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FX 3S |
FX 3G |
FX 3U |
FX 3GC |
FX 3UC |
|||||||||
FX3U-1PG | Independent one axis | 200kHz | × | × | *3 ○ Max. 8 units |
× | *1*3 ○ Max. 6 units |
||||||
FX2N-10PG | Independent one axis | 1MHz(1 Hz to 1 MHz differential line driver output) |
× | × | ○ Max. 8 units |
× | *1*2 ○ Max. 8 units |
*1: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.
*2: FX3UC-32MT-LT(-2): 7 units. FX3UC-**MT/D,FX3UC-**MT/DSS,FX3UC-16MR/D(S)-T: 8 units.
*3: FX3U, FX3UC supported from version 2.20 or later.
Model | Number of controlled axis |
Maximum frequency |
Applicable FX PLC | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FX 3S |
FX 3G |
FX 3U |
FX 3GC |
FX 3UC |
|||||||||
FX3U-20SSC-H | Two axes (Independent/Simultaneous) |
- | × | × | ○ Max. 8 units |
× | *1*2 ○ Max. 8 units |
*1: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.
*2: FX3UC-32MT-LT(-2): 7 units. FX3UC-**MT/D,FX3UC-**MT/DSS,FX3UC-16MR/D(S)-T: 8 units.
Model | Number of controlled axis |
Maximum requency |
Applicable FX PLC | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FX 3S |
FX 3G |
FX 3U |
FX 3GC |
FX 3UC |
|||||||||
FX2N-10GM | Independent one axis | 200kHz | × | × | ○ Max. 8 units |
× | *1*2 ○ Max. 8 units |
||||||
FX2N-20GM | Two axes (Independent/Simultaneous) |
200kHz |
*1: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.
*2: FX3UC-32MT-LT(-2): 7 units. FX3UC-**MT/D,FX3UC-**MT/DSS,FX3UC-16MR/D(S)-T: 8 units.
Model | Number of controlled axis |
Maximum frequency |
Applicable FX PLC | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FX 3S |
FX 3G |
FX 3U |
FX 3GC |
FX 3UC |
|||||||||
FX3U-2HSY-ADP | Independent two axes | 200kHz | × | × | * ○ Max. 2 units |
× | × |
*: When used together with analog or communication adapters, function expansion board is required
Model | Number of controlled axis |
Maximum frequency |
Applicable FX PLC | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FX 3S |
FX 3G |
FX 3U |
FX 3GC |
FX 3UC |
|||||||||
FX3U-1PG | Independent one axis | 200kHz | × | × | *3 ○ Max. 8 units |
× | *1*3 ○ Max. 6 units |
||||||
FX2N-10PG | Independent one axis | 1MHz(1 Hz to 1 MHz differential line driver output) |
× | × | ○ Max. 8 units |
× | *1*2 ○ Max. 8 units |
*1: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.
*2: FX3UC-32MT-LT(-2): 7 units. FX3UC-**MT/D,FX3UC-**MT/DSS,FX3UC-16MR/D(S)-T: 8 units.
*3: FX3U, FX3UC supported from version 2.20 or later.
Model | Number of controlled axis |
Maximum frequency |
Applicable FX PLC | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FX 3S |
FX 3G |
FX 3U |
FX 3GC |
FX 3UC |
|||||||||
FX3U-20SSC-H | Two axes (Independent/Simultaneous) |
- | × | × | ○ Max. 8 units |
× | *1*2 ○ Max. 8 units |
*1: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.
*2: FX3UC-32MT-LT(-2): 7 units. FX3UC-**MT/D,FX3UC-**MT/DSS,FX3UC-16MR/D(S)-T: 8 units.
Model | Number of controlled axis |
Maximum requency |
Applicable FX PLC | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FX 3S |
FX 3G |
FX 3U |
FX 3GC |
FX 3UC |
|||||||||
FX2N-10GM | Independent one axis | 200kHz | × | × | ○ Max. 8 units |
× | *1*2 ○ Max. 8 units |
||||||
FX2N-20GM | Two axes (Independent/Simultaneous) |
200kHz |
*1: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.
*2: FX3UC-32MT-LT(-2): 7 units. FX3UC-**MT/D,FX3UC-**MT/DSS,FX3UC-16MR/D(S)-T: 8 units
Model | Product |
E-20TP-SET0 (with E-20TP-CAB0) |
FX2N-10GM, FX2N-20GM |
E-20TP-E-SET0 (with E-20TP-CAB0) |
Model | Number of controlled axis |
Maximum frequency |
Applicable FX PLC | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FX 3S |
FX 3G |
FX 3U |
FX 3GC |
FX 3UC |
|||||||||
FX2N-1RM-SET*1 | One axis | 720 divisions/rotation (0.5 degree) or 360 divisions/rotation (1 degree) |
× | × | ○ Max. 3 units |
× | *2*3 ○ Max. 3 units |
||||||
FX2N-1RM-E-SET*1 |
*1: FX2N-1RM-SET is a Japanese domestic only product. For use overseas, please select FX2N-1RM-E-SET, which supports overseas standards.
*2: Extension cable cannot be used.
*3: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.
Items | FX3S | FX3G,FX3GC | FX3U,FX3UC | |
Number of axis | Two axes | [FX3G] Two axes (14/24 points) Three axes (40/60 points) [FX3GC] Two axes |
Three axes | |
Number of controlled axis | Independent two axes | [FX3G] Independent two axes (14/24 points) Independent three axes (40/60 points) [FX3GC] Independent two axes |
Independent three axes | |
Maximum frequency | 100 kHz | 100 kHz | 100 kHz | |
Programming languages | Sequence programs | Sequence programs | Sequence programs | |
Compatible main unit | Transistor output type main unit |
Transistor output type main unit |
Transistor output type main unit |
|
Pulse output instruction |
Pulse Y Output (PLSY) |
○ | ○ | ○ |
Acceleration/Deceleration Setup Pulse Y Output (PLSR) |
○ | ○ | ○ | |
Pulse output type | Pulse train (Direction is controlled by PLC program) |
Pulse train (Direction is controlled by PLC program) |
Pulse train (Direction is controlled by PLC program) |
|
Positioning instruction |
Absolute Current Value Read ([D]ABS) |
○ | ○ | ○ |
Dog Search Zero Return (DSZR) |
○ | ○ | ○ | |
Zero Return (ZRN) |
○*1 | ○*1 | ○*1 | |
Variable Speed Pulse Output (PLSV) |
○ | ○ | ○ | |
Drive to Increment (DRVI) |
○ | ○ | ○ | |
Drive to Absolute (DRVA) |
○ | ○ | ○ | |
Interrupt Positioning (DVIT) |
× | × | ○ | |
Batch Data Positioning Mode ([D]TBL) |
× | ○ | ○*2 | |
Pulse output type | Pulse train + direction | Pulse train + direction | Pulse train + direction | |
*1: No DOG search function Decelerate when near point DOG turns ON, and stop when near point DOG turns OFF (Different from zero return operation with zero signal count)
*2: FX3UC-32MT-LT supported from version 2.20 or later.
Model | Length | Description | |
E-GMH-200CAB | 2 m | [MR-H series servo amplifer connection cable] Can direcly connect FX2N-10GM/FX2N-20GM and servo amplifer. I/O operation signal part has 20-pin connector for connection to Mtisubishi terminal block. |
|
E-GMJ-200CAB | 2 m | [MR-J series servo amplifer connection cable] Can direcly connect FX2N-10GM/FX2N-20GM and servo amplifer. I/O operation signal part has 20-pin connector for connection to Mtisubishi terminal block. |
|
E-GMJ2-200CAB1A | 2 m | [MR-J2, MR-J2-Super series servo amplifer connection cable] Can direcly connect FX2N-10GM/FX2N-20GM and servo amplifer. |
|
E-GMC-200CAB | 2 m | [MR-C series servo amplifer connection cable] Can direcly connect FX2N-10GM/FX2N-20GM and servo amplifer. I/O operation signal part has 20-pin connector for connection to Mtisubishi terminal block. |
|
E-GM-200CAB | 2 m | [General purpose connection cable] Has connector on both sides. Can connect to general purpose drive unit via Mitsubishi terminal block. |
Model | Description | |
FX2C-I/O-CON | [Flat Cable Connector] AWG28 (0.1 mm2): A set of 10 pcs Crimp connector: FRC2-A020-3OS 1.27-pitch 20 cores Crimp tool: Separately arrange the tool manufactured by DDK Ltd. 357J-4674D Main Unit 357J-4664N Attachment |
|
FX2C-I/O-CON-S | [Connector for bared wire] AWG22 (0.3 mm2): 5 sets Housing: HU-200S2-001 Crimp contact: HU-411S Crimp tool: A product manufactured by DDK Ltd. is separately required. 357J-5538 |
|
FX2C-I/O-CON-SA | [Connector for bared wire] AWG20 (0.5mm2): 5 sets Housing: HU-200S2-001 Crimp contact: HU-411SA Crimp tool: A product manufactured by DDK Ltd. is separately required. 357J-13963 |
Model | Length | Description | |
FX2N-GM-65EC | 65 cm | [Connection extension cable between PLC and FX2N-10GM/FX2N-20GM] One cable cable can be used in a system. Standard connection cable (55mm) is included with FX2N-10GM/FX2N-20GM. |
|
F2-RS-5CAB | 5 m | [Resolver extension cable for FX2N-1RM] Resolver can be extended up to 100m extension by linking multiple cables. |
Model | Length | Description | |
(1) E-20TP-CAB0 | 3 m | [E-20TP connection cable] FX2N-10GM/FX2N-20GM (MINI DIN 8-pin) ⇔ E-20TP (MINI DIN 8-pin) Cable length is different between (1) and (2). (1) E-20TP-CAB0 (3 m) is included with E-20TP-SET0. |
|
(2) FX-20P-CAB0 | 1.5 m |
Model | Length | Description |
FX2N-GM-5EC | 55 mm | [Connection cable between PLC and FX2N-10GM/20GM] One cable is included with FX2N-10GM/20GM. |