For use within explosive plants

Description:

In many branches there exist explosive environments in manufacturing and following processes. To assure a preferably high level of safety in these areas, there exist conditions in terms of laws, orders and norms. For the use in these areas, there are Ex modules that are endorsed intrinsically-safe sensors and actuators being in zone 1 or 2 of explosive plants.

Area of application

The Ex modules are available to the automation of chemical plants as appropriate operating supplies. They are applicable for applications in the measurement-, control- and regulation technology. Areas of application:

Areas of application:

  • Chemical/petrochemical industry

  • Gas industry 

  • Offshore industry 

  • Transportation (e.g. tankers) 

  • Automotive engineering (e.g. at varnishing) 

  • Energy supply, energy distribution etc. 

  • Generating plants

  • Special engineering (e.g. printing machines, cleaning machines)

Benefit

The igniting protection type intrinsically-safe offers following advantages to the user:

  • Easy interchangeability of intrinsically-safe  equipment during the business

  • Easy measurement and calibration of the measuring section during the business

  • Working in intrinsically-safe  energized loops without stop of the plant

  • No complex case execution (e.g. compression-proof encapsulation) necessary

  • Linking of intrinsically-safe  equipment of different manufacturers possible

  • Approved igniting protection type in chemical industry

Design and functions

The main function of the digital Ex modules is the separation of the intrinsically-safe loops of the Ex field and the non intrinsically-safe internal loops of the automation plant.


The Ex digital input modules transform the level of the external binary signals of the intrinsically-safe equipment of the Ex field in an internal level of signals of the automation plant.
The Ex digital output modules transform the internal level of signals of the automation plant in external binary signals of the intrinsically-safe equipment of the Ex field.
Ex digital input/output modules are “appropriate electrical equipment” of the igniting protection type intrinsically-safe (term [EEx ib] IIC according to DIN EN 50020). You get next to intrinsically-safe ones also non intrinsically-safe loops.

  • Same systems engineering as the other modules of S7-300

  • Galvanic separation of the module

  • Confusion safety through coding

  • Supply of the sensors and actuators through the module

  • Direct wiring of the inputs and outputs of the modules without a separating switch amplifier or transmitter feed unit

  • Different wiring of the software possible

  • Diagnosis capable modules

  • Reduced  planning, installation and documentation effort


Operation also with ET 200M possible with connection to all SIMATIC automation systems and as norm slave to all PROFIBUS DP networks.


Technical specifications

Term  

Digital input

Digital output

Digital output

Channels 

4 DI NAMUR in 4 channel groups

4 DO DC 24V/10mA in 4 channel groups

4 DO DC 15V/20mA in 4 channel groups

Certificates, admissions, norms

     

igniting protection type according to EN 50020 (CENELEC)

II3 (2) GEEx nA [lib] IIC T4

II3 (2) GEEx nA [lib] IIC T4

II3 (2) GEEx nA [lib] IIC T4

igniting protection type according to FM

Class I, Division 2, Group A, B, C, D T4Class I, Zone 2, Group IIC T4

Class I, Division 2, Group A, B, C, D T4Class I, Zone 2, Group IIC T4

Class I, Division 2, Group A, B, C, D T4Class I, Zone 2, Group IIC T4

Test number PTB

KEMA 01ATEX1057 X

KEMA 01ATEX1059 X

KEMA 01ATEX1056 X

 
 

Products

C&M rovides a range of automation products from a number of manufacturers.

Our product range includes both automation building blocks like programmable logic controllers PLC's, Human Machine Interface HMI, industrial communication adapters, and customized products, like Compressor Management System and Battery Life Cycle Tester.

 

AB

Allen Bradley control solutions set the standard — from the original programmable logic controller (PLC) invented in the 1970s to the technology

customized

C&M Engineering has designed a reliable and robust compressor management system that is available as a customized product specifically configured according to your pressure demand.

MITSUBISHI

MITSUBISHI

Analog input modules provide an interface to the CPU for sensing variable real world levels of voltage and current signals. These signals are converted into digital values by the modules

Omron

Omron

The CP1E delivers an exceptional solution for automating small and compact machines, and is part of Omron’s Lean Automation concept.Lean Automation fits into stand-alone

Siemens

Siemens

Signal modules are the interface of SIMATIC S7-300 to the process. A host of different digital and analog modules provide exactly the inputs/outputs required for each task.

Thinget

Thinget

Thinget PLC is powered by Digital and Analogue Expansion modules, BD boards, motion controllers, PT100, Thermocouple Input

equipped with built-in PID controller, and high