Fail-safe S7-300 CPU

Description

The fail-safe SIMATIC controllers are used to guarantee the functional safety of machines or plants. They satisfy maximum safety requirements and comply with the relevant standards:
EN 954-1 up to Cat. 4, IEC 62061 up to SIL 3 and EN ISO 13849-1 up to PL e.
The simultaneous processing of the standard and the safety program means that only one CPU is required to handle both tasks.

Area of application

  • Automobile industry

  • General mechanical engineering

  • Building of special machines

  • Series mechanical engineering, OEM

  • Plastics processing

  • Packaging industry

  • Food- and Beverageindustry

Benefits

Reduction of stock-keeping by saving components

  •  One controller for standard and safety automation
    - Coexistence of standard and safety programs on one controller possible

  • One PROFIBUS or PROFINET transmitting medium for standard and safety communication to SIL 3/Category 4
    - One distributed I/O configuration with standard and safety I/O modules


Fast system configuration and commissioning

  • Better system integration     
    - Uniform engineering for standard and safety control component
    - Use of existing PROFIBUS or PROFINET transmitting medium even for safety  
      communication
    - Simple expansion of existing PROFIBUS archtictures about PROFINET, p.ex. via IE/PB-Link
      (SIMATIC NET)


More flexibility   

  • The logic of the safety functions is software-based rather than hard-wired
     
    - More easily modified, expanded and documented
    - Implementation of complex safety functions


Faster reproducibility

  • In contrast to the hardware solution, the software solution can be easily reproduced

  • Approved, certified solutions can often be used as self-contained blocks


Better retent of plant availability

  • Early fault detection thanks to better diagnostic functions

Investment security  

  • Easy migration from PROFIBUS to PROFINET

Standard and safety automation – divided into two systems – integrated in one system

Area of application

Because of their power and compactness, the safety SIMATIC S7-300F CPUs are ideal for meeting the demands of the mid to upper performance range. Both standard and safety-relevant tasks can be performed with only one CPU.

The SIMATIC S7-300F CPUs can be expanded centrally with the safety modules for the ET 200M I/O. Distributed expansion is possible using the safety ET 200S I/O modules, the ET 200M I/O modules, the ET 200pro (IP67) I/O modules or the safety digital block peripheral device ET 200eco (IP67).

Communication works depending on the CPU optional via MPI, PROFIBUS or PROFINET Interface.

SIMATIC S7-300 CPU 315F-2 DP

6ES7315-6FF04-0AB0

SIMATIC S7-300, CPU 315F-2DP Fail-safe module with MPI Integr. power supply 24 V DC, Work memory 384 KB, 40 mm width, 2nd interface DP master/slave Micro Memory Card required

CPU 315F-2 DP

The failsafe CPU with medium to large program memory and quantity framework for the use, if required, of SIMATIC Engineering Tools

  • High processing performance in binary and floating-point arithmetic

  • Distributed fail-safe I/O modules can be connected via the integral PROFIBUS DP interface (PROFIsafe)

SIMATIC S7-300 CPU 315F-2 PN/DP

6ES7315-2FJ14-0AB0

SIMATIC S7-300 CPU315F-2 PN/DP, Central processing unit with 512 KB work memory, 1st interface MPI/DP 12 Mbit/s, 2nd interface Ethernet PROFINET, with 2-port switch, Micro Memory Card required

CPU 315F-2 PN/DP

The failsafe CPU with a medium program memory and quantity framework

  • 40 mm width   

  • Integral PROFINET interface with 2 Ports for line topologies

  • High processing performance in binary and floating-point arithmetic

  • Fail-safe I/O modules in distributed stations can be connected through the integrated PROFINET interface (PROFIsafe) and/or through the integrated PROFIBUS DP interface (PROFIsafe)  

  • Component based Automation (CBA) on PROFINET

  • PROFINET-proxy for intelligent devices on PROFIBUS DPin Component Based Automation (CBA)

SIMATIC S7-300 CPU 317F-2 DP

6ES7317-6FF04-0AB0

SIMATIC S7-300, CPU 317F-2DP, Central processing unit with 1.5 MB work memory, 1st interface MPI/DP 12 Mbit/s, 2nd interface DP master/slave Micro Memory Card required Can be used with software package S7 Distributed Safety V5.2 SP1 or higher

CPU 317F-2 DP

The failsafe CPU with a large program memory and quantity framework for demanding requirements    

  • Distributed fail-safe I/O modules can be connected via the integral PROFIBUS DP interfaces (PROFIsafe)  


Product announcement:
The PROFIBUS CPU317 is also available as a fail-safe Technology Controller.
For more information see:

SIMATIC S7-300 CPU 317F-2 PN/DP

6ES7317-2FK14-0AB0

SIMATIC S7-300 CPU317F-2 PN/DP, Central processing unit with 1.5 MB work memory, 1st interface MPI/DP 12 Mbit/s, 2nd interface Ethernet PROFINET, with 2-port switch, Micro Memory Card required

CPU 317F-2 PN/DP

The failsafe CPU with a large program memory and quantity framework for demanding requirements

  • 40 mm width      

  • Integral PROFINET interface with 2 Ports for line topologies

  • Fail-safe I/O modules in distributed stations can be connected through the integrated PROFINET interface (PROFIsafe) and/or through the integrated PROFIBUS DP interface (PROFIsafe)     

  • Component based Automation (CBA) on PROFINET

  • PROFINET proxy for intelligent devices on PROFIBUS DPin Component Based Automation (CBA)

SIMATIC S7-300 CPU 319F-3 PN/DP

6ES7318-3FL01-0AB0

SIMATIC S7-300 CPU319F-3 PN/DP, Central processing unit with 2.5 MB work memory, 1st interface MPI/DP 12 Mbit/s, 2nd interface DP master/slave 3rd interface Ethernet PROFINET, Micro Memory Card required

CPU 319F-3 PN/DP

The failsafe CPU with highest processing performance, enlarged quantity framework and enhanced communication possibilities.

  • Integral PROFINET interface with 2 Ports for line topologies

  • Fail-safe I/O modules in distributed stations can be connected through the integrated PROFINET interface (PROFIsafe) and/or through the integrated PROFIBUS DP interface (PROFIsafe)   

  • Component based Automation (CBA) on PROFINET

  • PROFINET proxy for intelligent devices on PROFIBUS DPin Component Based Automation (CBA)

Technical data

 
 

 

  • Allen Bradley

Programmable Controllers

Allen Bradley control solutions set the standard — from the original programmable logic controller (PLC) invented in the 1970s to the technology embodied in the scalable, multi-disciplined and information-enabled programmable automation controller (PAC). Allen Bradley safety-certified controllers support your SIL 2 and SIL 3 application needs. Allen Bradley offer multiple controller types and sizes to fit your specific needs.


largecontrollerfamily front1 smprod
Large Control Systems

Allen Bradley Large Control Systems fit your most demanding application needs. They offer modular architectures and a range of I/O and network options. These powerful control solutions deliver world-class capabilities for all disciplines, from process to safety to motion. Designed for distributed or supervisory control applications, Allen Bradley large programmable automation controllers (PACs) and programmable logic controllers (PLC) provide exceptional reliability and performance.


smallcontrollerfamily front1 smprod

Small Control Systems 

The perfect solution for your mid-range applications, Allen Bradley small controllers offer the features and flexibility you need without the overhead of larger systems. Choose from standard and safety-certified controllers in chassis-based, packaged and modular designs. Typical applications include complex machine control, batch processing and building automation.


micronanocontrollerfamily front1 smprod

Micro & Nano Control Systems

Allen Bradley micro nano PLCs provide economical solutions to basic control needs for your simple machines ranging from relay replacement to simple control timing and logic. Compact packaging, integrated I/O and communication, and ease of use make these controllers an ideal choice for applications such as conveyor automation, security systems, and building and parking lot lighting.