• Address

    C-188, Sector 31-D, P&T Society,

    Korangi Industrial Area,

    Karachi-74900,

    Pakistan

     

  • Call us on

     +92-21-35070751

     +92-300-5776703

  • Mail us @

    info@pakplc.com

     

ADAM-5000/485

4-slot Distributed DA&C System Based on RS-485


Main Features

  • RS-485 Communication for easy installation and networking
  • 4 or 8 slots for up to 128 points data monitoning card control in one module
  • Extensive software support; Windows DLL, OCX, OPC server and popular HMI/SCADA software drivers
  • Seamlessly integrated with easy-to-use ADAMView data acquisition software
  • Supports ADAM ASCII protocol or ModbusR/RTU protocol
  • Supports Modbus/RTU protocol with user-defined Modbus address
  Datasheet (PDF)
Introduction

The ADAM-5000/485 and ADAM-5000E systems conform to the EIA RS-485 communication standard. This is the industry's most widely used, balanced, bidirectional transmission line standard. RS-485 was specifically developed for industrial applications to transmit and receive data at high rates over long distances.

Specifications
Part Number ADAM-5000/485-AE
Communications Communication 2500 VDC
Max.Nodes Depend on IP 
address
Protocol ADAM 
ASCII/Modbus 
Protocol
Control System CPU 80188
OS -
RAM -
Power Supply Power Requirement +10 ~ +30 VDC

ADAM-5000E

8-slot Distributed DA&C System for RS-485


Main Features

  • RS-485 Communication for easy installation and networking
  • 4 or 8 slots for up to 128 points data monitoring card control in one module
  • Extensive software support; Windows DLL, OCX, OPC server and popular HMI/SCADA software drivers
  • Seamlessly integrated with easy-to-use ADAMView data acquisition software
  • Supports ADAM ASCII protocol or Modbus®/RTU protocol
  • Supports Modbus/RTU protocol with user-defined Modbus address
  Datasheet (PDF)
Introduction

The ADAM-5000/485 and ADAM-5000E systems conform to the EIA RS-485 communication standard. This is the industry's most widely used, balanced, bidirectional transmission line standard. RS-485 was specifically developed for industrial applications to transmit and receive data at high rates over long distances.

Specifications
Part Number ADAM-5000E-AE
Communications Communication 3000 VDC
Max.Nodes 128
Protocol ADAM 
ASCII/Modbus 
Protocol
Control System CPU 80188
OS -
RAM -
Power Supply Power Requirement +10 ~ +30 VDC

ADAM-5000/TCP

8-slot Distributed DA&C System Based on Ethernet


Main Features

  • ARM 32-bit RISC CPU
  • 10/100Base-T auto-negotiation high-speed communication port
  • Supports Modbus/TCP for easy integration
  • Supports UDP event handling function
  • Up to 100 m communication distance w/o repeater
  • Allows remote configuration via Ethernet
  • Allows concurrent access for 8 host PCs
  • 4 I/O slots for up to 64 points and 8 I/O slots for up to 128 points data monitoring and control
  • 1500 VDC isolation for Ethernet communication
  • Built-in watchdog timer for system auto-reset
  • Windows utility
  • Provides ActiveX drivers to develop applications
  Datasheet (PDF)
Introduction

ADAM-5000L/TCP and ADAM-5000/TPC are both Ethernet-based I/O systems. Without a repeater, ADAM-5000L/TCP and ADAM-5000/TCP can cover a communication distance up to 100 m. This allows remote configuration via Ethernet and eight PCs can simultaneously access the data. The ADAM-5000L/TCP and ADAM-5000/TCP are the solutions for easy configuration and efficient management. It is an ideal and cost-effective solution for eAutomation architecture.

Specifications
Part Number ADAM-5000/TCP-BE
Communications Communication RS-485: 1500 VDC 
Ethernet: 3000 VDC
Max.Nodes Depend on IP 
address
Protocol Modbus/TCP
Control System CPU RISC CPU
OS real-time 
OS
RAM 4 MB
Power Supply Power Requirement +10 ~ +30 VDC

ADAM-5000L/TCP

4-slot Distributed DA&C System for Ethernet


Main Features

  • ARM 32-bit RISC CPU
  • 10/100Base-T auto-negotiation high-speed communication port
  • Supports Modbus/TCP for easy integration
  • Supports UDP event handling function
  • Up to 100 m communication distance w/o repeater
  • Allows remote configuration via Ethernet
  • Allows concurrent access for 8 host PCs
  • 4 I/O slots for up to 64 points and 8 I/O slots for up to 128 points data monitoring and control
  • 1500 VDC isolation for Ethernet communication
  • Built-in watchdog timer for system auto-reset
  • Windows utility
  • Provides .NET Class LIB to develop applications
  Datasheet (PDF)
Introduction

ADAM-5000L/TCP and ADAM-5000/TPC are both Ethernet-based I/O systems. Without a repeater, ADAM-5000L/TCP and ADAM-5000/TCP can cover a communication distance up to 100 m. This allows remote configuration via Ethernet and eight PCs can simultaneously access the data. The ADAM-5000L/TCP and ADAM-5000/TCP are the solutions for easy configuration and efficient management. It is an ideal and cost-effective solution for eAutomation architecture.

Specifications
Part Number ADAM-5000L/TCP-AE
Communications Communication RS-485: 1500 VDC 
Ethernet: 3000 VDC
Max.Nodes Depend on IP 
address
Protocol Modbus/TCP
Control System CPU RISC CPU
OS real-time 
OS
RAM 4 MB
Power Supply Power Requirement +10 ~ +30 VDC

  • Customized Solutions

Compressor Management System

Customized Solutions

CMS-6 is a specialized supervisory control product with advanced features and functions designed to provide energy efficient optimized narrow pressure and priority management control of up to 6 air / gas compressors operating in a common compressed air / gas system

C&M Engineering has designed a reliable and robust compressor management system that is available as a customized product specifically configured according to your pressure demand.