• Address

    C-188, Sector 31-D, P&T Society,

    Korangi Industrial Area,

    Karachi-74900,

    Pakistan

     

  • Call us on

     +92-21-35070751

     +92-300-5776703

  • Mail us @

    info@pakplc.com

     

automotive industry 2

Industry 1536x1536 Standard
services5

We are Pakplc

With over 32 years of experience

C&M Engineering, geographically located in Asia, business city Karachi the heart of Pakistan. Republic in southern Asia, at 23.30º to 36.45º north latitude, and 61º to 75.31º east longitude, bounded on the north and north-west by Afghanistan, on the north-east by China, on the east and south-east by India, on the south by the Arabian Sea and on the west by Iran. The area of Pakistan is 796,095 sq. km (307,374 sq. mi). The time zone of Pakistan is GMT+5. The capital of Pakistan is Islamabad, the largest city of the country is Karachi.
C&M established in 1986, helping manufacturers succeed and grow is what we do best — with industrial automation control and information solutions designed to give our customers a competitive advantage. From stand-alone, industrial components to enterprise-wide integrated systems, our solutions have proven themselves across a wide range of industries and in some of the most demanding manufacturing environments.

End users and machine builders (OEMs) alike rely on our comprehensive portfolio of equipment, software and serivices to deliver value and help them meet their objectives.

Recognized Expertise

We are recognized System Integrators for Siemens Factory Automation Products

Product development

In house development of Embedded Solutions

Pakistan Engineering Council

 

Siemens Approved System Integrator

channel partners small

cp1242 7 antenna small

The telecontrol communication processors offer a range of different possibilities for the implementation of extremely versatile and cost-efficient Telecontrol remote stations (RTUs) based on SIMATIC 
S7-1200. 

TeleControl Basic

TeleControl Basic is based on SIMATIC S7-1200 and secure transmission via mobile radio or the Internet. It is particularly suitable wherever small data quantities have to be transmitted over wireless connections or via the Internet. TeleControl Basic can be used as a low-cost fault signaling system, but thanks to the bidirectional communication facility, it is also suitable for simple telecontrol monitoring and control tasks. 
Together with the GPRS communication processor, the S7-1200 CPU supports simple Telecontrol applications for monitoring and control of distributed stations using general packet radio service (GPRS). The GPRS CP 1242-7 enables SMS messaging for event driven fault diagnostics. Additional full Teleservice functionally can be realized for remote diagnostics, configuration & programming.

The CP 1243-1 communications processor is used for connecting a SIMATIC S7-1200 to the TeleControl Server Basic control center software via Ethernet and for safe communication via IP-based networks in combination with an industrial router e.g. SCALANCE M. 

TeleControl Basic Components

 

CP 1242-7 For connection of SIMATIC S7-1200 to GSM/GPRS NET

cp1242 7 table

Order Information

Article No.

CP 1242-7 GPRS

6GK7 242-7KX30-0XE0

CP 1243-1 For connecting SIMATIC S7-1200 to TeleControl Server Basic 
via Ethernet also suited for safe communication with network with firewall and VPN

cp243 1 table

Order Information

Article No.

CP 1243-1

6GK7243-1BX30-0XE0

 
telecontrol proffessional small

TeleControl Professional

The communication processors CP 1243-1 DNP3 and CP 1243-1 IEC expand the TeleControl Professional portfolio with standardized remote control protocols. Both CP 1243-1 variants offer cycle and event-driven transmission of measured values and set values as well alarms between RTU and central control system without the need for costly programming. The connection to the control station over various public or private remote networks is performed via external modems/routers such as SCALANCE M, which are connected to the Ethernet interface of the CP. 

TeleControl Professional Components

 

CP 1243-1 DNP3 For connecting of SIMATIC S7-1200 
to Control Center with DNP3 protocol

cp1243 1 dnp3 table

Order Information

Article No.

CP 1243-1 DNP3

6GK7243-1JX30-0XE0

CP 1243-1 IEC for connecting SIMATIC S7-1200 
to Control Center with protocol IEC60870-5-104

cp1243 1 iec table

Order Information

Article No.

CP 1243-1 IEC

6GK7243-1PX30-0XE0

 

 

The CM CANopen enables you to connect any CANopen or CAN 2.0A devices to your SIMATIC S7-1200 PLC. The module plugs into your S7-1200 and acts as a bridge between the CANopen/CAN devices and the micro PLC. This allows you to choose from a wider range of automation products when designing your system.

CANopen and CAN 2.0A support

Simply attach the CM CANopen expansion module to the SIMATIC S7-1200 PLC. Any device running the CANopen protocol or any custom CAN 2.0A based protocol can then be connected.

Once attached to the S7-1200, you then set up the CM CANopen module from within TIA Portal®. Your CANopen network configuration can then be made in the accompanying CM CANopen Configuration Studio.

The CM CANopen module can be configured to be either a Master or Slave from TIA Portal. No programming is needed to create the configuration.

Highlights

  • Plug-in CANopen Master/Slave module for SIMATIC S7-1200 PLC

  • Connects up to 16 CANopen slave nodes in master mode

  • 256 byte input and 256 byte output per module

  • Connects up to 3 modules per CPU

  • 3 LEDs provide diagnostic information on module, network and I/O status

  • Integratable in the hardware catalogue of the TIA Portal configuration suite

  • Support for transparent CAN 2.0A for custom protocol implementation

  • CANopen configuration via the included CANopen Configuration Studio Software

  • Pre-made function blocks available for easy PLC programming in TIA portal

  • Complies to the CANopen communication profiles CiA 301 rev. 4.2 and the CiA 302 rev. 4.1

  • 3 year product guarantee. *

Communication module *

 

Order at HMS Anybus: 
CM CANopen-Modul, DSUB with screw connector for the subnet,
CD with CM CANopen Configuration Studio, USB-Configuration cable

cm canopen table

Note *:

The CM CANopen module is an HMS product and can only be obtained through HMS.

The following description contains information on supplementary products that are manufactured and marketed, not by Siemens, but by third-parties outside the Siemens group ("external companies"). These external companies organize the manufacture, sale and delivery of their products independently. Their own terms and conditions of business and delivery apply.
Responsibility for these supplementary products and for the associated information presented here rests exclusively with the respective external company. Unless compulsory by law, Siemens assumes no liability and makes no guarantee for supplemental products of external companies. Please refer also to the note on "Exemption from liability/Use of hyperlinks".

Exemption from liability/Use of hyperlinks

Siemens has prepared this description with great care. It is not possible, however, for Siemens to verify that the data supplied by external companies is complete, correct or up to date. The possibility that individual items of information might be incorrect, incomplete, or not up-to-date cannot therefore be ruled out. Unless compulsory by law, Siemens accepts no liability for the usability of the data or of the product for the user per se. 
This article contains third-party Web addresses. Siemens is not responsible for the contents of these Web sites, nor does Siemens adopt these Web sites and their contents, as Siemens does not control the presented information and cannot be held responsible for the content and information they contain. You therefore use these links at your own risk.

input simulator in cpu

The SIM 1274 Simulator Modules provide users the opportunity for testing user programs. Just mount the input simulator on the modular board instead of the digital inputs. So you could manual set input signal. This signal read by the CPU will be processed in the user program.

Article

Einsatz in

Article no.

Input Simulators Digital

 
input simulator digital 172

Simulator module SIM1274, 
8 channel DC Input switches

CPU 1211C/1212C

6ES7 274-1XF30-0XA0

Simulator module SIM1274, 
14 channel DC Input switches

CPU 1214C/1215C

6ES7 274-1XH30-0XA0

Simulator module SIM1274, 
14 Channel 
10x 24V DC Input switches, 
4X 1.5 V Differential Inputs

CPU 1217C

6ES7 274-1XK30-0XA0

Input Simulator Analog

 
input simulator digital 172 1

SIM1274 Analog simulator, 
2 Potentiometer inputs

for all CPUs 
of S7-1200

6ES7 274-1XA30-0XA0

sm1278 172

A continuous communication down to the lowest field level ensures enhanced use of the functions and performance capability of sensors and actuators. Enhanced use of sensors and actuators allows you to operate your machines and plants more productively.

No data other than the actual process value can be exchanged via the standard interfaces (digital, analog) used at the sensor/actuator level. Sensors and actuators with integrated intelligence are now used for increasingly complex functions and require a communication interface tailored to these requirements.

IO-Link is an innovative, point-to-point communication interface for the sensor/actuator area that is specified in IEC 61131-9.

IO-Link consists of the following system components:

  • IO-Link Master

  • IO-Link Device

  • Unshielded 3-wire standard cable

  • Engineering tool for configuring and assigning parameters of IO-Link

IO-Link Master module SM 1278

  • IO-Link master in accordance with IO-Link specification V1.1

  • Serial communication with 4 channels

  • Connection of 4 IO-Link devices per module (three-wire connection) or

  • Connection of 4 standard 24 V DC actuators

Article

Use in

Article no.

IO-LINK Master module SM 1278,
 4 X IO-LINK Master IO-LINK master V1.1

SIMATIC S7-1200

6ES7 278-4BD32-0XB0

Battery Board BB 1297

The S7-1200 BB 1297 Battery Board is designed for long-term backup of the Real-time clock.
It is pluggable in the signal board slot of the S7-1200 CPU (firmware 3.0 and later versions). You must add the BB 1297 to the device configuration and download the hardware configuration to the CPU for the BB to be functional.

The battery (type CR1025) is not included with the BB 1297 and must be purchased by the user.

 

Reverse engineering

Extensive reverse engineering service for obsolete controls

Maintenance services

Complete electronic and instrumentation maintenance service for all plants and machines

Green energy