Integrated profinet communication

IMATIC S7-1200 supports communication via PROFINET – the open, manufacturer-independent standard (IEC 61158/61784). PROFINET is 100% Ethernet and stands for maximum transparency, open standard communication via TCP/IP, network security and simultaneous real-time communication.

The integrated PROFINET interface in SIMATIC S7-1200 can be used for programming the CPU and for communication with SIMATIC HMI Basic Panels for visualization, but also for communication with other controllers or IO devices such as drives. 

The PROFINET cable is connected by means of a noise-immune RJ45 port with auto-crossover functionality supporting Ethernet connections and providing data transmission rates of up to 10/100 Mbit/s. For quick and error-free installation or changes on site, with FastConnect Siemens offer a sophisticated quick-assembly system consisting of cables, plug-in connectors and assembly tools. 

One of the advantages, thanks to PROFINET, is the integrated Web Server of the SIMATIC S7-1200. By means of the integrated Web server, information about the CPU as well as process data can be retrieved via a standard web browser. Data can also be archived from the user program during runtime. Furthermore, in firmware version 4.0, the CPUs possess the PROFINET iDevice functionality. The simplest way to configure multiple S7-1200 CPUs into a master-slave architecture: Each CPU process image is individually written and read.

cpu1215c profinet small

 

internal communication cables small

Simple networking

To minimize the cabling overhead and maximize the network flexibility, the CSM 1277 compact switch module can be used for configuring a homogenous or hybrid network – in linear, tree or star topologies. The CSM 1277 is a 4-port unmanaged switch which allows you to connect the SIMATIC S7-1200 with up to three additional devices.

Communication module

 

CSM 1277 Compact Switch Module

csm1277 table

Order Information

Article No.

CSM 1277,
10/100 Mbit/s 
4-port unmanaged switch, 
4 RJ45 Ports, 
Ext. 24V DC Power supply, 
LED Diagnostics

 

Communicationmodules 292x150

Each SIMATIC S7-1200 CPU can be expanded with as many as three communication modules. 
The RS485 and RS232 communication modules are suitable for serial, character-based point-to-point connections. 
The library functions USS Drive Protocol and Modbus RTU Master and Slave Protocol are already included in the SIMATIC STEP 7 basic engineering system.

tracking tracing small

Integration of identification systems

Using the RF120C communication module all SIMATIC identification systems (RF200/300/600 and optical reader system MV400) can be connected directly to the SIMATIC S7-1200. A reader can be connected to a RF120C via the point-to-point connection. The RF120C also provides a library with application blocks that are very easy to handle. Configuration is carried out via the TIA Portal.

Communication module

 

CM 1241 Communication module

cm1241 table

Order Information

Article No.

9-POL. Sub D (Male),
supports message based Freeport

 

CM 1241 RS232

6ES7 241-1AH32-0XB

CM 1241 RS422/485

6ES7 241-1CH32-0XB0

CB 1241 RS485 Communication board

cb1241 table

Order Information

Article No.

CB 1241 RS485 Communication board,
screw connector,
supports message based Freeport

6ES7 241-1CH30-1XB0

SIMATIC RF120C

rf120c table

Order Information

Article No.

RS422,
1 Reader connectable;

6GT2002-0LA00

 

cp1242 7 antenna small

Together with the GPRS communication processor, the S7-1200 CPU permits easy, wireless applications for controlling, monitoring and checking distributed stations using the general packet radio service (GPRS). This not only enables the remote control of machines via Teleserver Basic, but also the data recording. Apart from sending text message notifications for event-oriented fault diagnostics, the GPRS modules permit additional teleservice functions such as global remote diagnostics, configuration and programming.

Communication module

 

CP 1242-7 GPRS

cp1242 7 table

Order Information

Article No.

CP 1242-7 GPRS

6GK7 242-7KX30-0XE0

 

s7 1200 plus cm1243 5
 

The use of the SIMATIC S7-1200 as a master or slave on the proven PROFIBUS field bus facilitates standardized communication from the field level through to the control level. This meets one of the most important requirements in the performance range of compact automation.
For the connection of the S7-1200 to PROFIBUS there are two communication modules (CMs): The DP-Master CM 1243-5 enables as many as 16 field devices to be connected as slaves, e.g. ET 200 distributed I/O modules. Together with the CM 1242-5, the S7-1200 functions as a DP-Slave and can thus be connected to any DP-Master. Both modules are readily connected on the left of the CPU via the backplane bus.

 

Communication module

 

DP-Master CM 1243-5

cm1243 5 table

Order Information

Article No.

For connection of SIMATIC S7-1200 to PROFIBUS
as DP master module;
PG/OP communication

 

CM 1243-5 PROFIBUS DP Master

6GK7 243-5DX30-0XE0

CM 1242-5 PROFIBUS DP Slave

cm1242 5 table

Order Information

Article No.

For connection of SIMATIC S7-1200 to PROFIBUS
as DP slave module

 

CM 1242-5 PROFIBUS DP Slave

6GK7 242-5DX30-0XE0

asi cm1243 2 press small

AS-Interface

AS-i is an open, manufacturer-independent bus system that organizes the transmission of digital and analog process and machine signals into the control system. The AS-i Master communication module, as the "heart" of the AS-i Fieldbus can record sensors in the field or control actuators in the field.

The connection of an AS-i network to the SIMATIC S7-1200 is quite simple: the AS-i Master CM 1243-2 communication module is simply plugged into the CPU and wired to the field. The AS-i Master CM 1243-2 thus connects the lowest field level, such as IO modules, position switches, signaling columns, load feeders and motor starters with the higher-level SIMATIC S7-1200 control system. For each master, up to 62 AS-Interface slaves can be connected. All the advantages of the TIA Portal apply, such as the fully graphical parameter assignment and diagnostics of all AS-i stations without additional software.

Communication module

 

CM 1243-2 AS-i Master

asi cm1243 2 small

Order Information

Article No.

CM 1243-2 AS-i Master 
Communication module AS-INTERFACE master according AS-Interface Spec. V3.0

3RK7 243-2AA30-0XB0

IO-Link

IO-Link facilitates a fast and easy integration of the SIRIUS compact starter, M200D starter, SIRIUS soft-starter for a simple control of the starter function as well as for the simple use of IO devices from third-party suppliers. Likewise, RFID readers can quickly and easily be integrated via IO-Link.

IO-Link

 

IO-Link SM 1278

sm1278 i o link table

Order Information

Article No.

IO-Link Master SM 1278, 
4 X IO-Link Master V1.1

6ES7 278-4BD32-0XB0

Products

C&M rovides a range of automation products from a number of manufacturers.

Our product range includes both automation building blocks like programmable logic controllers PLC's, Human Machine Interface HMI, industrial communication adapters, and customized products, like Compressor Management System and Battery Life Cycle Tester.

 

AB

Allen Bradley control solutions set the standard — from the original programmable logic controller (PLC) invented in the 1970s to the technology

customized

C&M Engineering has designed a reliable and robust compressor management system that is available as a customized product specifically configured according to your pressure demand.

MITSUBISHI

MITSUBISHI

Analog input modules provide an interface to the CPU for sensing variable real world levels of voltage and current signals. These signals are converted into digital values by the modules

Omron

Omron

The CP1E delivers an exceptional solution for automating small and compact machines, and is part of Omron’s Lean Automation concept.Lean Automation fits into stand-alone

Siemens

Siemens

Signal modules are the interface of SIMATIC S7-300 to the process. A host of different digital and analog modules provide exactly the inputs/outputs required for each task.

Thinget

Thinget

Thinget PLC is powered by Digital and Analogue Expansion modules, BD boards, motion controllers, PT100, Thermocouple Input

equipped with built-in PID controller, and high