• Address

    C-188, Sector 31-D, P&T Society,

    Korangi Industrial Area,

    Karachi-74900,

    Pakistan

     

  • Call us on

     +92-21-35070751

     +92-300-5776703

  • Mail us @

    info@pakplc.com

     

sm1281 condition monitoring

The SIMATIC S7-1200 condition monitoring system is able to continually check up on the state of the mechanical components. In this way, it creates the basis for predictive maintenance. Users can respond promptly to impending damage and avoid the costly consequences that may include total failure. SIPLUS CMS1200 therefore makes acrucial contribution toward greater plant availability.

As many as 28 vibration sensors can be connected for each SIMATIC
S7-1200 CPU. The recorded data is analyzed by the internal software of the CMS1200 and stored on the SM 1281 condition monitoring module.

Benefits

  • Easy integration of the condition monitoring of mechanical components into the SIMATIC S7-1200 automation

  • Early detection of mechanical damage

  • Planned maintenance instead of spontaneous repair

  • No additional software for diagnostics and visualization

  • Easy archiving of the data

  • Further analysis options by means of raw data

The Condition Monitoring Module SM1281

  • Software for parameter-based and frequency-selective onboard analysis

  • Easy archiving of the data in the system’s own memory (800 MB)

  • Connection options:
    – 4 IEPE vibration-acceleration sensors per SM 1281
    – 1 rotary speed sensor per SM
    – Up to seven SM 1281 modules per S7-1200 CPU

Article

Use in

Article no.

Condition Monitoring Module SM 1281

SIMATIC S7-1200 
starting with CPU212

6AT8007-1AA10-0AA0

SIPLUS CMS1200 SM 1281 shield clamp set

SIMATIC S7-1200

6AT8007-1AA20-0AA0

SIPLUS CMS2000 VIB-SENSOR*

SIMATIC S7-1200

6AT8002-4AB00

SIPLUS CMS2000, CABLE-MIL-300*,
3m

SIMATIC S7-1200

6AT8002-4AC03

 

 

FX PLC Main Unit

catch

A wide lineup in FX series offers you many choices to fit to your budget and application.
You are sure to find a model that fulfills your needs.

FX Series Lineup
For high speed,
high functionality,
and expandability



Memory
64,000 step RAM memory built-in. Flash memory cassette can also be mounted.
Processing speed
Basic instruction: 0.065 μs/instruction (LD instruction) Application instruction: 0.642 to 100 μs/instruction
Device
Auxiliary relay: 7,680 pts Timer: 512 pts Counter: 235 pts Data register: 8,000 pts
Extension register: 32,768 pts Extension file register (optional memory): 32,768 pts
Application instruction
List of supported application instructions

For high speed,
reduced wiring,
reduced space



Memory
64,000 step RAM memory built-in. Flash memory cassette can also be mounted.
Processing speed
Basic instruction: 0.065 μs/instruction (LD instruction) Application instruction: 0.642 to 100 μs/instruction
Device
Auxiliary relay: 7,680 pts Timer: 512 pts Counter: 235 pts Data register: 8,000 pts
Extension register: 32,768 pts Extension file register (optional memory): 32,768 pts
Application instruction
List of supported application instructions

For communication,
analog expansions,
and up to 256 I/O control



Memory
32,000 step EEPROM memory built-in. Battery-free and maintenance-free.
Processing speed
Basic instruction: 0.21μs/instruction (in standard mode) 0.42μs/instruction (in extension mode)
Application instruction: 0.5 to 100 μs/instruction (in standard mode) 1.2 to 100 μs/instruction (in extension mode)
Device
Auxiliary relay: 7,680 pts Timer: 320 pts Counter: 235 pts Data register: 8,000 pts
Extension register: 24,000 pts Extension file register: 24,000 pts
Application instruction
List of supported application instructions

*1: 14pt, 24pt models can only connect 1 board
*2: 14pt, 24pt models have 2 independent axes
For reduced space and
reduced wiring



Memory
32,000 step EEPROM memory built-in. Battery-free and maintenance-free.
Processing speed
Basic instruction: 0.21 μs/instruction (in standard mode) 0.42 μs/instruction (in extension mode)
Application instruction: 0.5 to 100 μs/instruction (in standard mode) 1.2 to 100 μs/instruction (in extension mode)
Device
Auxiliary relay: 7,680 pts Timer: 320 pts Counter: 235 pts Data register: 8,000 pts
Extension register: 24,000 pts Extension file register: 24,000 pts
Application instruction
List of supported application instructions

For communication,
analog expansions,
and low cost



Memory
16,000 step EEPROM memory built-in. Battery-free and maintenance-free.
(Program capacity is 4,000 steps)
Processing speed
Basic instruction: 0.21 μs/instruction
Application instruction: 0.5 to 100μs/instruction
Device
Auxiliary relay: 1,536 pts Timer: 138 pts Counter: 67 pts Data register: 3,000 pts
Application instruction
List of supported application instructions

 

Explanation of the icons
Depending on control points, total 256 I/O extension devices can be connected.
*Includes CC-Link remote I/O
FX3U/FX3UC can count at high speed input frequency 100kHz (1-phase 6pts), 50kHz (2-phase 2pts), 10kHz (1-phase 2pts).
Depending on control points, total 384 I/O extension devices can be connected.
*Includes CC-Link remote I/O
FX3S/FX3GC has 2 axes simple positioning function built into the main unit.
Depending on the purpose, various special function blocks can be connected.
FX3G/FX3U/FX3UChas 3 axes simple positioning built into the main unit.
*FX3G 14 pt, 24 pt models have independent 2 axes.
Function can be easily added by mounting a function expansion board to the main unit.
I/O can be connected in connector format, reducing wiring effort.
In FX3UC-32MT-LT, CC-Link/LT master functionality is built-in.
1 phase: 60 kHz x 4 pts/ 10 kHz x 2 pts    2 phase: 30 kHz x 2 pts/ 5 kHz 1 pt
1 phase: 60 kHz x 2 pts/ 10 kHz x 4 pts     2 phase: 30 kHz x 1 pt/ 5 kHz 1 pt
In FX3S-30MR/ES-2AD, FX3S-30MT/ES-2AD, and FX3S-30MT/ESS-2AD, 2ch analog input (current input) function is built-in.
 
 

Extension units

Powered extension units are I/O extension devices with built-in power supply.

Like with the main unit, various I/O devices and special devices can be connected after a powered extension unit.

Model Total number
of points
Number of input/output points
Input/output type
Applicable FX PLC
Input Output FX
3S
FX
3G
FX
3U
FX
3GC
FX
3UC
AC Power Type
FX2N-32ER 32 points 16 points 24 V DC
(sink)
16 points Relay × × ×
FX2N-32ER-ES/UL 24 V DC
(sink/
source)
FX2N-32ES 24 V DC
(sink)
Triac
FX2N-32ET 24 V DC
(sink)
Transistor
(sink)
FX2N-32ET-ESS/UL 24 V DC
(sink/
source)
Transistor
(source)
FX2N-48ER 48 points 24 points 24 V DC
(sink)
24 points Relay × × ×
FX2N-48ER-ES/UL DC24V
(sink/
source)
FX2N-48ET 24 V DC
(sink)
Transistor
(sink)
FX2N-48ET-ESS/UL 24 V DC
(sink/
source)
Transistor
(source)
FX2N-48ER-UA1/UL 48 points 24 points 100 V AC 24 points Relay × × ×
DC Power Type
FX2N-48ER-D 48 points 24 points 24 V DC
(sink)
24 points Relay × × ×
FX2N-48ER-DS 24 V DC
(sink/
source)
FX2N-48ET-D 24 V DC
(sink)
Transistor
(sink)
FX2N-48ET-DSS 24 V DC
(sink/
source)
Transistor
(source)

 


Regarding connection cable

A connection cable (length: 55mm), used to connect to the the right side of the device in front of the powered extension unit, is included with the powered extension unit.
To extend the distance of the connection, please use the optional "extension cable".

 

Function expansion board

The expansion board is designed to add the input and output terminal whose points are small to FX3S or FX3G PLCs. The board can be built in the PLC.

Model Total
number
of
points
Number of input/output points
Input/output type
Applicable FX PLC
Input Output FX
3S
FX
3G
FX
3U
FX
3GC
FX
3UC
FX3G-4EX-BD 4
points
4
points
24 V DC
(sink/
source)
- - *1

Max.
1 unit
*2

Max.
1 unit
× × ×
FX3G-2EYT-BD 2
points
- - 2
points
Transistor
(sink/
source)
*1

Max.
1 unit
*2

Max.
1 unit
× × ×

 


*1: Supported by FX3S ver.1.10 and later.

*2: Supported by FX3G ver.2.20 and later.

 

Extension blocks

Extension block is an I/O extension device that receives power from the main unit or powered extension unit.

It can be connected in 8 point or 16 point units. The connectable number of points is determined by each main unit or powered extension unit

Model Total number
of points
Number of input/output points
Input/output type
Applicable FX PLC
Input Output FX
3S
FX
3G
FX
3U
FX
3GC
FX
3UC
Input/output extension blocks
FX2N-8ER 8 points 4 points
(8 devices
are occupied.)
24 V DC
(sink)
4 points
(8 devices
are occupied.)
Relay × *1
*2

*1
*2

FX2N-8ER-ES/UL DC24V
(sink/
source)
FX2N-8EX 8 points 24 V DC
(sink)
- -
FX2N-8EX-ES/UL DC24V
(sink/
source)
FX2N-8EX-UA1/UL 100 V AC
FX2N-16EX 16 points 16 points 24 V DC
(sink)
× *1
*2

*1
*2

FX2N-16EX-ES/UL 24 V DC
(sink/
source)
FX2N-16EX-C
Connector input
24 V DC
(sink)
FX2N-16EXL-C
Connector input
5 V DC
Output extension blocks
FX2N-8EYR 8 points - - 8 points Relay × *1
*2

*1
*2

FX2N-8EYR-ES/UL
FX2N-8EYR-S-ES/UL Relay
(8 points/common)
FX2N-8EYT Transistor
(sink)
FX2N-8EYT-H
FX2N-8EYT-ESS/UL Transistor
(source)
FX2N-16EYR 16 points 16 points Relay × *1
*2

*1
*2

FX2N-16EYR-ES/UL
FX2N-16EYS Triac
FX2N-16EYT Transistor
(sink)
FX2N-16EYT-ESS/UL Transistor
(source)
FX2N-16EYT-C
Connector output
Transistor
(sink)


*1 :For connection to FX3GC or FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.

*2 :Depending on the model name of the main unit, I/O extension device connection may or may not be allowed. For details, refer to the manual of the main unit.


Regarding connection cable

A connection cable, used to connect to the right side of the device in front of the extension block, is included with the extension block.

To extend the distance of the connection, please use the optional "extension cable (FX0N-30EC/FX0N-65EC)" and "connector conversion adapter (FX2N-CNV-BD)".

 

Extension block for connector type main unit (FX3GC, FX3UC)

These I/O extension devices can be directly connected to FX1NC, FX3GC, FX2NC, FX3UC PLCs.

They can be compactly extended because connection cables are not needed.

Model Total number
of points
Number of input/output points
Input/output type
Applicable FX PLC
Input Output FX
3S
FX
3G
FX
3U
FX
3GC
FX
3UC
Input extension blocks
FX2NC-16EX-T
Terminal block input
16 points 16 points 24 V DC
(sink)
- - × × × *
*
FX2NC-16EX-T-DS
Terminal block input
DC24V
(sink/
source)
FX2NC-16EX DC24V
(sink)
FX2NC-16EX-DS DC24V
(sink/
source)
FX2NC-16EX-D/UL DC24V
(sink)
FX2NC-32EX 32 points 32 points 24 V DC
(sink)
FX2NC-32EX-DS DC24V
(sink/
source)
FX2NC-32EX-D/UL DC24V
(sink)
Output extension blocks
FX2NC-16EYR-T
Terminal block Output
16 points - - 16 points Relay × × × *
*
FX2NC-16EYR-T-DS
Terminal block output
FX2NC-16EYT Transistor
(sink)
FX2NC-16EYT-DSS Transistor
(source)
FX2NC-16EYT-D/UL Transistor
(sink)
FX2NC-32EYT 32 points 32 points Transistor
(sink)
FX2NC-32EYT-DSS Transistor
(source)
FX2NC-32EYT-D/UL Transistor
(sink)
Input/output extension blocks
FX2NC-64ET 64 points 32 points 24 V DC
(sink)
32 points Transistor
(sink)
× × × *
*

 

*: Depending on the model name of the main unit, I/O extension device connection may or may not be allowed. For details, refer to the manual of the main unit

 

High speed counter block/adapter

Model
(Number of channels)
Type Highest response
frequency
Hardware comparison
output function
2-phase counter
edge count function
Applicable FX PLC
FX
3S
FX
3G
FX
3U
FX
3GC
FX
3UC
FX2N-1HC
(1ch)
1-phase
1-count
Max. 50 kHz - × ×
Max.
8 units
× *2*3

Max.
8 units
1-phase
2-count
Max. 50 kHz
2-phase
2-count
1 edge count:
Max. 50 kHz
2 edge count:
Max. 25 kHz
4 edge count:
Max. 12.5 kHz
FX3U-2HC
(2ch)
1-phase
1-count
Max. 200 kHz - × ×
Max.
8 units
× *2

Max.
4 units
1-phase
2-count
Max. 200 kHz
2-phase
2-count
1 edge count:
Max. 200 kHz
2 edge count:
Max. 100 kHz
4 edge count:
Max. 50 kHz
FX2NC-1HC
(1ch)
1-phase
1-count
Max. 50 kHz - × × × × *3

Max.
8 units
1-phase
2-count
Max. 50 kHz
2-phase
2-count
1 edge count:
Max. 50 kHz
2 edge count:
Max. 25 kHz
4 edge count:
Max. 12.5 kHz
FX3U-4HSX-ADP
(4ch)
1-phase
1-count
Max. 200 kHz × × × *1

Max.
2 units
× ×
1-phase
2-count
Max. 200 kHz
2-phase
2-count
1 edge count:
Max. 100 kHz
4 edge count:
Max. 100 kHz

*1: When used together with analog or communication adapters, function expansion board is required.
*2: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.
*3: FX3UC-32MT-LT(-2): 7 units. FX3UC-**MT/D,FX3UC-**MT/DSS,FX3UC-16MR/D(S)-T: 8 units.

 

High-speed output special adapter

Model Number of
controlled axis
Maximum
frequency
Applicable FX PLC
FX
3S
FX
3G
FX
3U
FX
3GC
FX
3UC
FX3U-2HSY-ADP Independent two axes 200kHz × × *

Max.
2 units
× ×

*: When used together with analog or communication adapters, function expansion board is required

Pulse output block

Model Number of
controlled axis
Maximum
frequency
Applicable FX PLC
FX
3S
FX
3G
FX
3U
FX
3GC
FX
3UC
FX3U-1PG Independent one axis 200kHz × × *3

Max.
8 units
× *1*3

Max.
6 units
FX2N-10PG Independent one axis 1MHz(1 Hz to 1 MHz
differential line driver output)
× ×
Max.
8 units
× *1*2

Max.
8 units

*1: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.
*2: FX3UC-32MT-LT(-2): 7 units. FX3UC-**MT/D,FX3UC-**MT/DSS,FX3UC-16MR/D(S)-T: 8 units.
*3: FX3U, FX3UC supported from version 2.20 or later.

 

SSCNET

Model Number of
controlled axis
Maximum
frequency
Applicable FX PLC
FX
3S
FX
3G
FX
3U
FX
3GC
FX
3UC
FX3U-20SSC-H Two axes
(Independent/Simultaneous)
- × ×
Max.
8 units
× *1*2

Max.
8 units

*1: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.
*2: FX3UC-32MT-LT(-2): 7 units. FX3UC-**MT/D,FX3UC-**MT/DSS,FX3UC-16MR/D(S)-T: 8 units.

 

Positioning dedicated unit

Model Number of
controlled axis
Maximum
requency
Applicable FX PLC
FX
3S
FX
3G
FX
3U
FX
3GC
FX
3UC
FX2N-10GM Independent one axis 200kHz × ×
Max.
8 units
× *1*2

Max.
8 units
FX2N-20GM Two axes
(Independent/Simultaneous)
200kHz

*1: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.
*2: FX3UC-32MT-LT(-2): 7 units. FX3UC-**MT/D,FX3UC-**MT/DSS,FX3UC-16MR/D(S)-T: 8 units.

 

  • Siemens
Siemens offers a wide range of Programmable Logic Controllers (PLC). S7-1200 PLC is suitable for small individual machine applications, whereas S7-300 PLC was previously targeted towards medium to high demand applications. However since it is nearing its end-of-lifecycle, S7-300/400 PLC series have been supplemented with the innovative S7-1500 PLC series. A new range of HMI panels are also available in all sizes for suitable operator control/monitoring. S7-1200 and S7-1500 are both part of Totally Integrated Automation (TIA) platform and programmable via Siemens TIA Portal software.
Simatic 300

          SIMATIC S7-300

 
Simatic 1200

         SIMATIC S7-1200

 
Simatic 1500

         SIMATIC S7-1500

 

s7 400

          SIMATIC S7-400

 
Simatic HMI

          SIMATIC HMI