C&M Engineering, geographically located in Asia, business city Karachi the heart of Pakistan. Republic in southern Asia, at 23.30º to 36.45º north latitude, and 61º to 75.31º east longitude, bounded on the north and north-west by Afghanistan, on the north-east by China, on the east and south-east by India, on the south by the Arabian Sea and on the west by Iran. The area of Pakistan is 796,095 sq. km (307,374 sq. mi). The time zone of Pakistan is GMT+5. The capital of Pakistan is Islamabad, the largest city of the country is Karachi.
C&M established in 1986, helping manufacturers succeed and grow is what we do best — with industrial automation control and information solutions designed to give our customers a competitive advantage. From stand-alone, industrial components to enterprise-wide integrated systems, our solutions have proven themselves across a wide range of industries and in some of the most demanding manufacturing environments.

End users and machine builders (OEMs) alike rely on our comprehensive portfolio of equipment, software and serivices to deliver value and help them meet their objectives.

Recognized Expertise

We are recognized System Integrators for Siemens Factory Automation Products

Product development

In house development of Embedded Solutions

Pakistan Engineering Council

 

Siemens Approved System Integrator

channel partners small

ADAM-5000/485

4-slot Distributed DA&C System Based on RS-485


Main Features

  • RS-485 Communication for easy installation and networking
  • 4 or 8 slots for up to 128 points data monitoning card control in one module
  • Extensive software support; Windows DLL, OCX, OPC server and popular HMI/SCADA software drivers
  • Seamlessly integrated with easy-to-use ADAMView data acquisition software
  • Supports ADAM ASCII protocol or ModbusR/RTU protocol
  • Supports Modbus/RTU protocol with user-defined Modbus address
  Datasheet (PDF)
Introduction

The ADAM-5000/485 and ADAM-5000E systems conform to the EIA RS-485 communication standard. This is the industry's most widely used, balanced, bidirectional transmission line standard. RS-485 was specifically developed for industrial applications to transmit and receive data at high rates over long distances.

Specifications
Part Number ADAM-5000/485-AE
Communications Communication 2500 VDC
Max.Nodes Depend on IP 
address
Protocol ADAM 
ASCII/Modbus 
Protocol
Control System CPU 80188
OS -
RAM -
Power Supply Power Requirement +10 ~ +30 VDC

ADAM-5000E

8-slot Distributed DA&C System for RS-485


Main Features

  • RS-485 Communication for easy installation and networking
  • 4 or 8 slots for up to 128 points data monitoring card control in one module
  • Extensive software support; Windows DLL, OCX, OPC server and popular HMI/SCADA software drivers
  • Seamlessly integrated with easy-to-use ADAMView data acquisition software
  • Supports ADAM ASCII protocol or Modbus®/RTU protocol
  • Supports Modbus/RTU protocol with user-defined Modbus address
  Datasheet (PDF)
Introduction

The ADAM-5000/485 and ADAM-5000E systems conform to the EIA RS-485 communication standard. This is the industry's most widely used, balanced, bidirectional transmission line standard. RS-485 was specifically developed for industrial applications to transmit and receive data at high rates over long distances.

Specifications
Part Number ADAM-5000E-AE
Communications Communication 3000 VDC
Max.Nodes 128
Protocol ADAM 
ASCII/Modbus 
Protocol
Control System CPU 80188
OS -
RAM -
Power Supply Power Requirement +10 ~ +30 VDC

ADAM-5000/TCP

8-slot Distributed DA&C System Based on Ethernet


Main Features

  • ARM 32-bit RISC CPU
  • 10/100Base-T auto-negotiation high-speed communication port
  • Supports Modbus/TCP for easy integration
  • Supports UDP event handling function
  • Up to 100 m communication distance w/o repeater
  • Allows remote configuration via Ethernet
  • Allows concurrent access for 8 host PCs
  • 4 I/O slots for up to 64 points and 8 I/O slots for up to 128 points data monitoring and control
  • 1500 VDC isolation for Ethernet communication
  • Built-in watchdog timer for system auto-reset
  • Windows utility
  • Provides ActiveX drivers to develop applications
  Datasheet (PDF)
Introduction

ADAM-5000L/TCP and ADAM-5000/TPC are both Ethernet-based I/O systems. Without a repeater, ADAM-5000L/TCP and ADAM-5000/TCP can cover a communication distance up to 100 m. This allows remote configuration via Ethernet and eight PCs can simultaneously access the data. The ADAM-5000L/TCP and ADAM-5000/TCP are the solutions for easy configuration and efficient management. It is an ideal and cost-effective solution for eAutomation architecture.

Specifications
Part Number ADAM-5000/TCP-BE
Communications Communication RS-485: 1500 VDC 
Ethernet: 3000 VDC
Max.Nodes Depend on IP 
address
Protocol Modbus/TCP
Control System CPU RISC CPU
OS real-time 
OS
RAM 4 MB
Power Supply Power Requirement +10 ~ +30 VDC

ADAM-5000L/TCP

4-slot Distributed DA&C System for Ethernet


Main Features

  • ARM 32-bit RISC CPU
  • 10/100Base-T auto-negotiation high-speed communication port
  • Supports Modbus/TCP for easy integration
  • Supports UDP event handling function
  • Up to 100 m communication distance w/o repeater
  • Allows remote configuration via Ethernet
  • Allows concurrent access for 8 host PCs
  • 4 I/O slots for up to 64 points and 8 I/O slots for up to 128 points data monitoring and control
  • 1500 VDC isolation for Ethernet communication
  • Built-in watchdog timer for system auto-reset
  • Windows utility
  • Provides .NET Class LIB to develop applications
  Datasheet (PDF)
Introduction

ADAM-5000L/TCP and ADAM-5000/TPC are both Ethernet-based I/O systems. Without a repeater, ADAM-5000L/TCP and ADAM-5000/TCP can cover a communication distance up to 100 m. This allows remote configuration via Ethernet and eight PCs can simultaneously access the data. The ADAM-5000L/TCP and ADAM-5000/TCP are the solutions for easy configuration and efficient management. It is an ideal and cost-effective solution for eAutomation architecture.

Specifications
Part Number ADAM-5000L/TCP-AE
Communications Communication RS-485: 1500 VDC 
Ethernet: 3000 VDC
Max.Nodes Depend on IP 
address
Protocol Modbus/TCP
Control System CPU RISC CPU
OS real-time 
OS
RAM 4 MB
Power Supply Power Requirement +10 ~ +30 VDC

Reverse engineering

Extensive reverse engineering service for obsolete controls

Maintenance services

Complete electronic and instrumentation maintenance service for all plants and machines

Green energy