• Address

    C-188, Sector 31-D, P&T Society,

    Korangi Industrial Area,

    Karachi-74900,

    Pakistan

     

  • Call us on

     +92-21-35070751

     +92-300-5776703

  • Mail us @

    info@pakplc.com

     

automotive industry 2

Industry 1536x1536 Standard
services5

We are Pakplc

With over 32 years of experience

C&M Engineering, geographically located in Asia, business city Karachi the heart of Pakistan. Republic in southern Asia, at 23.30º to 36.45º north latitude, and 61º to 75.31º east longitude, bounded on the north and north-west by Afghanistan, on the north-east by China, on the east and south-east by India, on the south by the Arabian Sea and on the west by Iran. The area of Pakistan is 796,095 sq. km (307,374 sq. mi). The time zone of Pakistan is GMT+5. The capital of Pakistan is Islamabad, the largest city of the country is Karachi.
C&M established in 1986, helping manufacturers succeed and grow is what we do best — with industrial automation control and information solutions designed to give our customers a competitive advantage. From stand-alone, industrial components to enterprise-wide integrated systems, our solutions have proven themselves across a wide range of industries and in some of the most demanding manufacturing environments.

End users and machine builders (OEMs) alike rely on our comprehensive portfolio of equipment, software and serivices to deliver value and help them meet their objectives.

Recognized Expertise

We are recognized System Integrators for Siemens Factory Automation Products

Product development

In house development of Embedded Solutions

Pakistan Engineering Council

 

Siemens Approved System Integrator

channel partners small

ADAM-5018P

7-ch Thermocouple Input Module with Independent Input Range


Main Features

  • High Common Mode: 2000 VDC
  • Fault and Overvoltage Protection: Withstands over voltage up to ±35 V
  • Isolation Voltage: 3,000 VDC
  • Filter function: Yes
  • Built-in TVS/ESD Protection
  • Input Impedance: 20 MΩ. (Build-in 120 Ω Register for Current Input)
  • Channels: 7 differential with Independent Input Range
  • CMR @ 50/60 Hz: 92 dB min
  • Sampling Rate: 10 samples/sec. (total)
  • Accuracy Bandwidth: ±0.1% or better, 13.1 Hz @ 50 Hz, 15.72 Hz @ 60 Hz
  Datasheet (PDF)
Introduction

ADAM-5018P is a 16-bit, 7-channel thermocouple input module that features programmable independent input ranges on each channel. It accepts millivolt inputs (±15 mV, ±50 mV, ±100 mV, ±500 mV), voltage inputs (±1V, ±2.5 V), current input (±20 mA, 4~20 mA, requires 120 ohms resistor) and thermocouple input (J, K, T, R, S, E, B). The module forwards the data to the host computer in engineering units (mV, V, mA or temperature °C). It also accepts high common mode up to 200 Vdc and has many protections built in, like over voltage, isolation voltage, filter and TVS/ESD function. An external CJC on the plug-in terminal is designed for accurate temperature measurement.

Specifications
Part Number ADAM-5018P-AE
Analog Input Current 
Input
± ±20 mA 20 mA
Direct Sensor Input J, K, T, E, 
R, S, B
Input Channels 7
Resolution 16 bits
Sampling Rate 10
Voltage 
Input
±15 mV 
±50 mV 
±100 mV 
± 500 mV 
±1 V 
±2.5 V
Analog Output Resolution -
Protection Isolation 3000 VDC
Digital I/O Digital Input Channel -
Digital Ouput Channel -

ADAM-5024

4-ch Analog Output Module


Main Features

  • Channels: 4
  • Effective resolution: 12-bit
  • Output type: mA, V
  • Output range: 0 ~ 20 mA, 4 ~ 20 mA, 0 ~10 V
  • Isolation voltage: 3000 VDC
  • Accuracy: ±0.1% of FSR for current output
  • Resolution: ±0.015% of FSR
  Datasheet (PDF)
Introduction

The ADAM-5024 is a 4-channel analog output module. It receives the digital input from the ADAM-5000 system or the host computer on RS-485 network. The format of the data is engineering units. It then uses the D/A converter controlled by the system module to convert the digital data into output signals. You can specify slew rates and start up currents through the configuration software. The analog output can also be configured as current or voltage through the software utility. The module protects your equipment from ground loops and power surges by providing optical isolation of the D/A output and transformer based isolation up to 500 VDC.

Specifications
Part Number ADAM-5024-AE
Analog Input Current 
Input
-
Direct Sensor Input -
Input Channels -
Resolution -
Sampling Rate -
Voltage 
Input
-
Analog Output Resolution 12 bits
Protection Isolation 3000 VDC

ADAM-5050

16-ch Universal Digital I/O Module


Main Features

  • Channels: 16
  • I/O Type: bit-wise selectable by DIP switch
  • Digital input: Support Dry/Wet Contact
  • Digital output: Open Collector to 30 V, 450 mW max. load
  • Power consumption: 0.35 W (typical); 1.2 W (max)
  Datasheet (PDF)
Introduction

The ADAM-5050 features sixteen digital input/output channels. Each channel can be independently configured to be an input or an output channel by the setting of its DIP switch. The digital outputs are open-collector transistor switches that can be controlled from the ADAM-5000. The switches can also be used to control solid-state relays, which in turn can control heaters, pumps and power equipment. The ADAM-5000 can use the module's digital inputs to determine the state of limit or safety switches, or to receive remote digital signals.

Specifications
Part Number ADAM-5050-AE
Communications Channels -
Type -
Counter (32-bit) Channels -
Input Frequency -
Mode -
Digital I/O Digital Input Channel 16 DIO 
bit-wise 
selectable
Digital Ouput Channel 16 DIO 
bit-wise 
selectable

ADAM-5024

4-ch Analog Output Module


Main Features

  • Channels: 4
  • Effective resolution: 12-bit
  • Output type: mA, V
  • Output range: 0 ~ 20 mA, 4 ~ 20 mA, 0 ~10 V
  • Isolation voltage: 3000 VDC
  • Accuracy: ±0.1% of FSR for current output
  • Resolution: ±0.015% of FSR
  Datasheet (PDF)
Introduction

The ADAM-5024 is a 4-channel analog output module. It receives the digital input from the ADAM-5000 system or the host computer on RS-485 network. The format of the data is engineering units. It then uses the D/A converter controlled by the system module to convert the digital data into output signals. You can specify slew rates and start up currents through the configuration software. The analog output can also be configured as current or voltage through the software utility. The module protects your equipment from ground loops and power surges by providing optical isolation of the D/A output and transformer based isolation up to 500 VDC.

Specifications
Part Number ADAM-5024-AE
Analog Input Current 
Input
-
Direct Sensor Input -
Input Channels -
Resolution -
Sampling Rate -
Voltage 
Input
-
Analog Output Resolution 12 bits
Protection Isolation 3000 VDC

ADAM-5051

16-ch Digital Input Modules


Main Features

  • Channels: 16
  • Input voltage: 30 Vmax
  • Circuit type: Pull-Up current: 0.5 mA (Source Type)
  • Power consumption: 0.53 W
 
Introduction

The ADAM-5051 provides sixteen digital input channels. The ADAM-5000 system can use the module's digital inputs to determine the state of limit or safety switches or to receive remote digital signals.

Specifications
Part Number ADAM-5051-AE
Communications Channels -
Type -
Counter (32-bit) Channels -
Input Frequency -
Mode -
Digital I/O Digital Input Channel 16 
16w/LED
Digital Ouput Channel -

Reverse engineering

Extensive reverse engineering service for obsolete controls

Maintenance services

Complete electronic and instrumentation maintenance service for all plants and machines

Green energy

Striving to reduce carbon foot-print, and extensively involved in deployment of renewable energy projects.